2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and Their Applications (ANIMM 2013
DOI: 10.1109/animma.2013.6728083
|View full text |Cite
|
Sign up to set email alerts
|

Fission chamber simulator for data acquisition performance tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…In order to fully test the Pulse Preamplifier block at the operation condition of the reactor, a special permit and significant time resources were required. In this regard, a device that simulates the FC signals in different modes is necessary to design and fabricate [6]. FC signal simulator allows us to generate a model signal of FC in a wide range of pulse rates, i.e.…”
Section: Discussionmentioning
confidence: 99%
“…In order to fully test the Pulse Preamplifier block at the operation condition of the reactor, a special permit and significant time resources were required. In this regard, a device that simulates the FC signals in different modes is necessary to design and fabricate [6]. FC signal simulator allows us to generate a model signal of FC in a wide range of pulse rates, i.e.…”
Section: Discussionmentioning
confidence: 99%
“…In semi-natural modeling it is advisable to use a full-scale sample of a data acquisition system (a prototype, for example) and an I&C complex (fission chamber signal simulator [3,4]), which implements the mathematical model of forming the FC signal with set parameters and provides an output of an electric pulse-current signal.…”
Section: Mixed Experimental and Computational Methodsmentioning
confidence: 99%
“…High time resolution transducers (see above), at fixed positions above the notches, allow coding versus the depth of the notches: 4 levels of depth for example, which results in a great number of coding combinations. An important feature of the study is the use of a resilient " [7,4]" Hamming coding algorithm and of a parity control matrix, in order to detect and correct some possibilities of misreading due to notches defects, or transducers misalignments, and/or to transducers failure.…”
Section: Ultrasonic Measurements Telemetry Inspection and Imagingmentioning
confidence: 99%
“…Actually Imaging concerns radiographic and tomographic "X-ray" imaging which is in fact "Bremsstrahlung photon" 4 imaging with the highest possible spatial resolution. Design calculations and modeling are carried out by using Monte-Carlo transport codes and specific photon (and neutron) imaging tool.…”
Section: Active Photon Measurementsmentioning
confidence: 99%
See 1 more Smart Citation