International audienceNuclear heating measurements in Material Testing Reactors are crucial for the design of the experimental devices and the prediction of the temperature of the hosted samples. Indeed, nuclear heating is a key input data for the computer codes which simulate temperature reached by samples under irradiation. In the Jules Horowitz Reactor under construction at the CEA Cadarache, the maximal expected nuclear heating levels will be about 15 to 18 W/g and it will be necessary to measure this key parameter with the best accuracy. An experiment was led at the OSIRIS reactor to compare the measurements between the two most appropriate sensors for measuring nuclear heating in MTR; a differential calorimeter and a gamma thermometer. A specific differential calorimeter was designed for low nuclear heating and a standard gamma thermometer was used. Experimental results and Monte-Carlo simulations show that the two sensors are suitable even if the measured energy deposit is different in the two sensors. Finally, these comparisons between the measurements recall that it is primordial to precise in which material and environment the nuclear heating is measured to use this key parameter for designing experimental devices in MTR
Abstract-The nuclear radiation energy deposition rate (unit usually employed: W.g -1 ) is a key parameter for the thermal design of experiments on materials and nuclear fuel carried out in experimental channels of irradiation reactors, such as the French reactor in Saclay called OSIRIS or the Polish reactor named MARIA. In particular the quantification of nuclear heating allows the prediction of heat and thermal conditions induced in irradiated devices and/or structural materials. Various sensors are used to quantify this parameter, in particular radiometric calorimeters, also known as in-pile calorimeters. Two main kinds of in-pile calorimeter exist possessing two geometries and two measurement principles: the single-cell calorimeter and the differential calorimeter. The present work focuses on specific examples of these calorimeter types, from the step of their out-of-pile calibration (transient and steady experiments respectively) to the comparison between numerical and experimental results obtained from two irradiation campaigns (French and Polish reactors). The main aim of this paper is to propose a steady numerical approach to estimate the single-cell calorimeter response under irradiation conditions.
In the framework of the European I-Smart project, optimal 4H-SiC based diode geometries were developed for high temperature neutron detection. Irradiation tests were conducted with 14 MeV fast neutrons supplied by a deuteriumtritium neutron generator with an average neutron yield of 4.04 × 10 10 − 5.25 × 10 10 n/s at Neutron Laboratory of the Technical University of Dresden in Germany. In this paper, we interpret the first measurements and results with 4H-SiC detector irradiated with fast neutrons from room temperature up to 500 • C. These experiments are serving also the first simulation of the harsh environmental condition measurements in the tritium breeding blanket of the ITER fusion reactor, which is one of the most prominent planned location of high temperature neutron flux characterization studies in the near future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.