2022
DOI: 10.1016/j.epsr.2022.107927
|View full text |Cite
|
Sign up to set email alerts
|

Flexible reactive power management using PV inverter overrating capabilities and fixed capacitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…Nowadays, commercial smart inverters present this capability and can vary its operating point in order to introduce reactive power to the grid. However, the reactive power is a function of the generated active power (Figure 1), limiting its operation [15]. From the technical point of view, the local management of the reactive power can improve the grid operation with an adjustment of the voltage level in a line, when the appropriate control loop and signal are sent to the smart inverters [16].…”
Section: Local Reactive Powermentioning
confidence: 99%
“…Nowadays, commercial smart inverters present this capability and can vary its operating point in order to introduce reactive power to the grid. However, the reactive power is a function of the generated active power (Figure 1), limiting its operation [15]. From the technical point of view, the local management of the reactive power can improve the grid operation with an adjustment of the voltage level in a line, when the appropriate control loop and signal are sent to the smart inverters [16].…”
Section: Local Reactive Powermentioning
confidence: 99%
“…So, l is added in the equation to represent random variation over time in the range of (0, 1). In equation (26), the constant (β 1 ) is selected to be 2 and the integer number (μ) is randomly taken between 0 and 1. Besides, the time coefcient (tc) is a value that changes with each iteration, and its value depends entirely on the maximum iteration number (It Max ) and the current iteration number (It).…”
Section: Initial Population Generationmentioning
confidence: 99%
“…In addition, a few other studies have analyzed the benefts for voltage regulation, loss reduction, and congestion mitigation through integrating photovoltaic inverter to generate reactive power [24,25]. In the DGU integrated system, the inverter can be used for injecting or absorbing reactive power to maximize the achieved economic and technical welfare [26]. For the optimization problem in generating the active and reactive powers, the power factor of DGUs needs to be considered and parameter should be inserted accordingly [27].…”
Section: Introductionmentioning
confidence: 99%
“…This technique allows selecting the distributed energy resource that can provide reactive power by limiting the reactive power supplied by the transmission system operator, thus reducing losses. In [23] was developed a reactive power methodology considering photovoltaic inverter capabilities and fixed capacitors. A mixed integer secondorder conic programming model is used, minimizing the maintenance and operation cost of compensation devices, thus confirming a considerable reduction in investment and energy losses in distribution grids.…”
Section: Introductionmentioning
confidence: 99%