2018
DOI: 10.1016/j.jcsr.2018.08.011
|View full text |Cite
|
Sign up to set email alerts
|

Flexural behavior of rebar truss stiffened cold-formed U-shaped steel-concrete composite beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(9 citation statements)
references
References 14 publications
0
9
0
Order By: Relevance
“…It has good bending bearing capacity and ductility, as well as good construction convenience, fire resistance and economic performance. Liu Jiepeng et al (2018, 2019), Zhao Yi et al (2019), Xiao et al (2005) et al proposed the design method of shear connection, bearing capacity and stiffness of UCB through a series of experimental research and theoretical analysis.…”
Section: Introductionmentioning
confidence: 99%
“…It has good bending bearing capacity and ductility, as well as good construction convenience, fire resistance and economic performance. Liu Jiepeng et al (2018, 2019), Zhao Yi et al (2019), Xiao et al (2005) et al proposed the design method of shear connection, bearing capacity and stiffness of UCB through a series of experimental research and theoretical analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Based on the results of the parametric study, an analytical formula for calculating the force transfer capacity of the shear connector was developed. For the varus-type top flange USCCB, Zhou's research group investigated the flexural behavior [21,22], shear behavior [23], and torsional behavior [24] of a novel cold-formed U-shaped steel-concrete composite beam constituted using a truss-type and inverted U-shaped reinforcement bar system.…”
Section: Introductionmentioning
confidence: 99%
“…us, several forms of shear connectors have been reported for enhancing the flexural behavior or eliminating the constitution difficulty of composite beams [14][15][16][17][18][19][20][21][22]. Park et al [14,15] used diagonal rebars and welded rebar connections to strengthen the beam-column joints.…”
Section: Introductionmentioning
confidence: 99%
“…Ductile failure mode and high strength were observed with all specimens, and the depth of U-shaped girder was found to be the most sensitive affecting parameter on the flexural behavior of the composite beams. Zhou et al [20] and Liu et al [21] discussed the flexural behavior of the rebar truss stiffened cold-formed U-shaped steel-concrete composite beams, in which the interface between the concrete slab and U-shaped girder was enhanced with inverted U-shaped rebars. rough experimental results, the midspan deflection of the composite beams can reach up to L 0 / 20, reflecting a good deformability.…”
Section: Introductionmentioning
confidence: 99%