2008
DOI: 10.1007/s11094-008-0088-8
|View full text |Cite
|
Sign up to set email alerts
|

Flow-injection estimation of 2-aminophenol in pharmaceutical agents using piezoquartz immunosensors

Abstract: A flow piezoquartz immunosensor was developed for the rapid estimation of 4-aminophenol in pharmaceutical formulations based on paracetamol. The bioreceptor coating was a 4-aminophenol-protein conjugate (4-AP-GA-BSA), immobilized on the silanized surface of a silver electrode. The effects of the concentration of polyclonal antibodies on the analytical signal of the sensor were studied: the activities of immunological reagents were assessed in terms of the binding constant K b . A method for flow-injection esti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 6 publications
(6 reference statements)
0
5
0
Order By: Relevance
“…[4][5][6][7] Nevertheless, even in the variant developed here, TLIA provides a good screening opportunity for small molecules in combination with another immunoassay. 22 In our opinion, further enhancements in the analytical parameters can be achieved by developing more traceable procedures for antibody immobilization at a polymer surface including dual-surface treatment, 25 which could provide at least two-fold enhancement in sensitivity. As well, tracers with higher absorptivity/lower quantum yields, which are almost not in use today due to the low sensitivity of spectrophotometric measurements, may prove very expedient in TLIA.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…[4][5][6][7] Nevertheless, even in the variant developed here, TLIA provides a good screening opportunity for small molecules in combination with another immunoassay. 22 In our opinion, further enhancements in the analytical parameters can be achieved by developing more traceable procedures for antibody immobilization at a polymer surface including dual-surface treatment, 25 which could provide at least two-fold enhancement in sensitivity. As well, tracers with higher absorptivity/lower quantum yields, which are almost not in use today due to the low sensitivity of spectrophotometric measurements, may prove very expedient in TLIA.…”
Section: Resultsmentioning
confidence: 99%
“…Finally, from the viewpoint of trace analysis, TLIA combines the well-known advantages of ELISA and flowinjection immunoassays 22,24,25 and provides online preconcentration of the target hapten, both for the batch and flow modes. Therefore, TLS-based immunoassays for small molecules may widen the applications of immunochemical analysis.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations