“…In the current study using the H1NMR spectra phosphate residues were detected at the 0.1 ppm. Furthermore, correlation signal was observed for a C2H-R3 (H1) peak at 4-5.1 ppm [22,26]. According to the Vinogradov and his colleague's study, a glycerol teichoic acid H1NMR spectrum has shown N-acetyl glucosamine residues at the 2.1-2.3 ppm (H2-H6) as well as glycerol residues at 3.8-4 ppm which our data confirmed the obtained results in previous researches [26].…”
Section: Resultssupporting
confidence: 90%
See 2 more Smart Citations
“…In the current study using the H1NMR spectra phosphate residues were detected at the 0.1 ppm. Furthermore, correlation signal was observed for a C2H-R3 (H1) peak at 4-5.1 ppm [22,26]. According to the Vinogradov and his colleague's study, a glycerol teichoic acid H1NMR spectrum has shown N-acetyl glucosamine residues at the 2.1-2.3 ppm (H2-H6) as well as glycerol residues at 3.8-4 ppm which our data confirmed the obtained results in previous researches [26].…”
Section: Resultssupporting
confidence: 90%
“…The spectra (NMR) of Gly-TA show signals attributable to (CH3)-3HPO4 residues at the 0.4 ppm. Similar data has been obtained in previous studies [22,25] (Details have been shown in Fig. 3).…”
Section: Resultssupporting
confidence: 90%
See 1 more Smart Citation
“…Two classes of flow probes have been designed depending on the position of the sample tube, which can be vertical (denoted below as type 1) or horizontal (denoted below as type 2) ( Fig. 1 ), and the shape of the RF coil for transmitting and receiving, namely saddle-shaped when the sample tube is placed vertically and solenoidal when the sample tube is placed horizontally [ 14 ]. Manufacturers have designed commercial NMR flow probes of type 1 that can be integrated into their high and low-resolution NMR instruments.…”
Section: Reviewmentioning
confidence: 99%
“…For the design of a NMR flow probe, similarly to the design of a new probe head, careful choice of the components should be made in order to have an optimal resolution, sensitivity and RF homogeneity, but in addition, other factors should be taken into account because of working on-flow. Hence, the design should allow a high filling factor, the flash out of air bubbles and the displacement of the existing fluid in the detection volume by the incoming fluid instead of just mix with it, among other issues [ 14 ]. Hence, the flow cell is a sample tube (made of glass or quartz) with openings at the top (outlet) and at the bottom (inlet) to enable connection to the flow system.…”
Section: Reviewmentioning
confidence: 99%