Forehead electrodes sufficiently detect propofol-induced slow waves for the assessment of brain function after cardiac arrest

Abstract: In a recent study, we proposed a novel method to evaluate hypoxic ischemic encephalopathy (HIE) by assessing propofolinduced changes in the 19-channel electroencephalogram (EEG). The study suggested that patients with HIE are unable to generate EEG slow waves during propofol anesthesia 48 h after cardiac arrest (CA). Since a low number of electrodes would make the method clinically more practical, we now investigated whether our results received with a full EEG cap could be reproduced using only forehead elect… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
13
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(13 citation statements)
references
References 22 publications
0
13
0
Order By: Relevance
“…The findings are in line with results of a previous pilot study indicating similar association during controlled propofol sedation at 48 h after ROSC. 17,20 In the current study, we show the association in a larger patient group with routine propofol sedation and continuously recorded SWA from the ICU admission until 48 h from ROSC. We also utilize an approach clinically suitable for ICU environment including a practical EEG recording and automatic parametrization of SWA using C-Trend Index.…”
Section: Discussionmentioning
confidence: 52%
See 1 more Smart Citation
“…The findings are in line with results of a previous pilot study indicating similar association during controlled propofol sedation at 48 h after ROSC. 17,20 In the current study, we show the association in a larger patient group with routine propofol sedation and continuously recorded SWA from the ICU admission until 48 h from ROSC. We also utilize an approach clinically suitable for ICU environment including a practical EEG recording and automatic parametrization of SWA using C-Trend Index.…”
Section: Discussionmentioning
confidence: 52%
“…17 Further exploration of the data showed that the SWA was sufficiently captured by a reduced frontal electrode set. 20 In this prospective multicenter study, we investigated the accuracy of EEG SWA in predicting the outcome of comatose CA survivors during propofol sedation. We hypothesized that low SWA during propofol sedation in the first 48 h after CA would be associated with poor outcome.…”
Section: Introductionmentioning
confidence: 99%
“…The proposed method requires no auxiliary reference signal and no specific feature extraction. The method was shown to be suitable in detecting artifacts from recordings collected with an easy-to-use electrode and device suitable for demanding clinical environment such as ICU where electrode attachment with minimum preparation is highly appreciated [25]. [26,27].…”
Section: Conclusion and Discussionmentioning
confidence: 99%
“…At the same time, spatial correlation is also considered in this method, as it is applicable the recordings of multiple channels. Moreover, our aim was to train and validate a simple deep learning-based artifact removal method and explore its performance considering only forehead EEG data which has been proved to be effective in intensive care units (ICUs) where securely maintaining electrodes' contact and providing long-term highquality signal acquisition are essential [21].…”
Section: Introductionmentioning
confidence: 99%