2000
DOI: 10.1006/mvre.2000.2255
|View full text |Cite
|
Sign up to set email alerts
|

Formation and Actions of Cyclic ADP-Ribose in Renal Microvessels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

2
20
0

Year Published

2002
2002
2017
2017

Publication Types

Select...
4
4
1

Relationship

2
7

Authors

Journals

citations
Cited by 29 publications
(22 citation statements)
references
References 44 publications
2
20
0
Order By: Relevance
“…The superfusate (PSS) in the bath was bubbled with 95% O 2-5% CO2 and maintained at pH 7.4 and 37°C. This condition for isolated artery preparation was chosen based on a number of previous studies (3,34,43,47,59). Because there is no hemoglobin in the superfusate, enough O 2 supply is needed to maintain tissue PO2 for normal endothelial and VSM function.…”
Section: Microdissection and Microperfusion Of Small Coronary Arterymentioning
confidence: 99%
See 1 more Smart Citation
“…The superfusate (PSS) in the bath was bubbled with 95% O 2-5% CO2 and maintained at pH 7.4 and 37°C. This condition for isolated artery preparation was chosen based on a number of previous studies (3,34,43,47,59). Because there is no hemoglobin in the superfusate, enough O 2 supply is needed to maintain tissue PO2 for normal endothelial and VSM function.…”
Section: Microdissection and Microperfusion Of Small Coronary Arterymentioning
confidence: 99%
“…Because there is no hemoglobin in the superfusate, enough O 2 supply is needed to maintain tissue PO2 for normal endothelial and VSM function. By adjusting bubbling rate, an appropriate balance of O 2 supply and consumption could be reached, which maintains an appropriate environment for studies of vasomotor responses in this isolated artery preparation (34,43,59). The internal diameter of arteries was measured with a video system composed of a stereomicroscope (Leica MZ8), a charge-coupled device camera (KP-MI AU, Hitachi), a video monitor (VM-1220U, Hitachi), a video measuring apparatus (VIA-170, Boeckeler Instrument), and a video printer (UP890 MD, Sony).…”
Section: Microdissection and Microperfusion Of Small Coronary Arterymentioning
confidence: 99%
“…This delay was attributed to the time required for the SR Ca 2+ content to be increased following SERCA activation by cADPR (Lukyanenko et al, 2001). This proposal could explain the frequently observed pronounced delay in the onset of cADPR activity (Cui et al, 1999;Aarhus et al, 1995;Li et al, 2000).…”
mentioning
confidence: 95%
“…In membrane preparations of aorta (13,53), renal microvessels (39), coronary arteries (31,52,55), and pulmonary artery (16), evidence for ADPR cyclase activity has been demonstrated. Measurement of changes in [Ca 2ϩ ] i in response to cADPR has been made in permeabilized renal VSM cells (39). To our knowledge, there have been no Ca 2ϩ studies examining the activation of the cADPR pathway in intact fresh afferent arterioles and no studies exploring the effect of ANG II on this particular pathway in VSM of any origin.…”
mentioning
confidence: 99%