2020
DOI: 10.1088/1757-899x/890/1/012159
|View full text |Cite
|
Sign up to set email alerts
|

Formation and motion of droplets in gas cleaning devices with porous rotating atomizers

Abstract: This paper presents the study of characteristics of porous rotating nozzles recommended for use in gas cleaning devices. The influence of geometrical and technological parameters of atomizer on the size of droplets and the trajectory of their motion is investigated theoretically and experimentally. To determine the droplet size when it is detached from the spherical granule of porous rotating atomizers (PRA), the simulation in the Flow3D program was used. A model for calculating the droplets tra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…In the workshops of the enterprise, emissions of carbon monoxide are observed, sulfur dioxide is emitted -at sinter plants, in the blast furnace shop and in the mixing department of steel-making shops, although the concentration of sulfur dioxide in the air does not exceed the maximum permissible (10 mg/m 3 ), gas emissions and dust are also observed, predominantly in shops and in the areas of charge preparation (contains up to 15-20 % and more free and amorphous silicon dioxide, over 50 % of iron oxides and other impurities); noise (from 90 and over 100 dB) [22][23][24].…”
Section: Methodsmentioning
confidence: 99%
“…In the workshops of the enterprise, emissions of carbon monoxide are observed, sulfur dioxide is emitted -at sinter plants, in the blast furnace shop and in the mixing department of steel-making shops, although the concentration of sulfur dioxide in the air does not exceed the maximum permissible (10 mg/m 3 ), gas emissions and dust are also observed, predominantly in shops and in the areas of charge preparation (contains up to 15-20 % and more free and amorphous silicon dioxide, over 50 % of iron oxides and other impurities); noise (from 90 and over 100 dB) [22][23][24].…”
Section: Methodsmentioning
confidence: 99%
“…There are known studies in which to stabilize the operation of the exhaust ventilation system of buildings for various purposes it is proposed to design modular ejection systems [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…The adoption of federal and regional regulations in the field of energy conservation indicates the existence of problems in the thermal power sector. The objectives of improving energy efficiency and energy saving of such critical building engineering systems as heat supply and ventilation are considered by many researchers [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%