2016
DOI: 10.1016/j.dental.2016.03.003
|View full text |Cite
|
Sign up to set email alerts
|

Fracture toughness of chairside CAD/CAM materials – Alternative loading approach for compact tension test

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
32
1
8

Year Published

2017
2017
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 65 publications
(43 citation statements)
references
References 53 publications
2
32
1
8
Order By: Relevance
“…We did not observe other technical complications such as crown fracture, chipping, or loss of retention despite one patient having had a parafunctional habit (yet did not use a night‐guard); this compares favorably with findings reported by others . Even when it was determined that there was inadequate occlusal thickness in monolithic LDGC crowns; there was a relatively low rate of fracture …”
Section: Discussionmentioning
confidence: 70%
See 1 more Smart Citation
“…We did not observe other technical complications such as crown fracture, chipping, or loss of retention despite one patient having had a parafunctional habit (yet did not use a night‐guard); this compares favorably with findings reported by others . Even when it was determined that there was inadequate occlusal thickness in monolithic LDGC crowns; there was a relatively low rate of fracture …”
Section: Discussionmentioning
confidence: 70%
“…[3][4][5] Even when it was determined that there was inadequate occlusal thickness in monolithic LDGC crowns; there was a relatively low rate of fracture. [30][31][32] Overall, patients were very satisfied with the esthetic outcomes (94.0% for color and 91.0% for shape) as recorded using the VAS questionnaire. This finding was higher than another report on patients' esthetic satisfaction of MC crowns (82.0%).…”
Section: Discussionmentioning
confidence: 96%
“…Difference in size and distribution of the crystalline phase is also responsible for different behaviors of materials. 28 In the present study, difference in distribution of filler particles, fabrication process, and rate of polymerization (degree of conversion) led to difference in fracture toughness of composite resins.…”
Section: Discussionmentioning
confidence: 62%
“…The present study found that 1-mm hybrid ceramics performed significantly better in the fatigue test compared with 0.5-mm ZLS. This may be associated with the fact that the microstructure of PIC contains polymer-filled pores, and this combination of materials aims to increase fracture resistance as well as resistance to flexion [29][30][31][32][33]. Elastic modulus and fracture resistance are factors that must be taken into account in the selection of materials, since they are directly related to the materials' behavior against loads.…”
Section: Discussionmentioning
confidence: 99%