Free-field sound power levels of open-inlet/open-outlet fans and comparison with in-duct measurements

Abstract: Sound power levels were measured for an axial-flow fan and a centrifugal fan, both having 600-mm-diam impellers. One-third-octave-band sound power levels were measured by microphones at essentially free-field locations and in the test ducts for two installation configurations: "1… an open inlet and an anechoic outlet duct and "2… an open outlet and an anechoic inlet duct. Two parallelepiped ''rectangular box'' measurement surfaces and a hemispherical measurement surface were used for free-field tests. The requ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

1999
1999
2009
2009

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…For engineering grade accuracy measurements, the environmental correction has to be K )2 dB over the entire frequency range of interest. In a European round-robin test, it was found not possible to satisfy this criterion for all frequencies (see references [42,43]). In the latter study, values of as much as K "4 dB were observed at certain frequencies, despite the fact that the environmental test conditions were favourable, considering practical situations.…”
Section: Discussionmentioning
confidence: 99%
“…For engineering grade accuracy measurements, the environmental correction has to be K )2 dB over the entire frequency range of interest. In a European round-robin test, it was found not possible to satisfy this criterion for all frequencies (see references [42,43]). In the latter study, values of as much as K "4 dB were observed at certain frequencies, despite the fact that the environmental test conditions were favourable, considering practical situations.…”
Section: Discussionmentioning
confidence: 99%
“…The sound powers are measured using a 1/2" microphone flush-mounted on the duct. According to Neise (1995), in the frequency range of higher-order mode sound propagation, the induct sound power levels were lower than the freefield sound power levels. Table 3 gives the measured sound power indices of the rotational speed for each case of non-uniform inflow conditions.…”
Section: Methodsmentioning
confidence: 99%