1969
DOI: 10.1021/jf60165a023
|View full text |Cite
|
Sign up to set email alerts
|

Freeze concentration of volatile components in dilute aqueous solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

1969
1969
2021
2021

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…Volatile acids and bases can be converted to their salt-forms to minimize volatility losses during lyophilization [22]. Freeze concentration has been used for the concentration of aqueous solutions of organic volatiles and of substances which are heat labile [8,11,23]. For successful results, the contact layers between the liquid and solid phases should be continuously disturbed by stirring or shaking and part of the solution should remain unfrozen at the end of the concentrating procedure.…”
Section: Isolation and Concentration Techniques Using Physical Methodsmentioning
confidence: 99%
“…Volatile acids and bases can be converted to their salt-forms to minimize volatility losses during lyophilization [22]. Freeze concentration has been used for the concentration of aqueous solutions of organic volatiles and of substances which are heat labile [8,11,23]. For successful results, the contact layers between the liquid and solid phases should be continuously disturbed by stirring or shaking and part of the solution should remain unfrozen at the end of the concentrating procedure.…”
Section: Isolation and Concentration Techniques Using Physical Methodsmentioning
confidence: 99%
“…FC was suggested as a sample preparation technique for the analysis of trace components in aqueous solutions as early as 1961 [20][21][22][23][24][25][26], but has not been widely accepted as a routine sample preparation technique. FC has advantages compared to other concentration methods, including extended operational duration and relatively low cost [18].…”
Section: Sbse Is a Solvent-free Sample Preparation Technique First Rementioning
confidence: 99%
“…More elaborate systems include the use of a cold finger or stainless-steel beaker to partially freeze the sample (Kepner et al 1969). While freeze concentration seems to be an ideal process and should be used whenever the flavor chemist has an aqueous flavor isolate, it seldom is employed in flavor studies.…”
Section: Freeze Concentrationmentioning
confidence: 99%