“…The limits of detection (LOD) and quantication (LOQ) were found to be 0.1600 and 0.4801 mg mL −1 , respectively. The results of this sensor transcended some reported methods for gabapentin detection, particularly the spectrophotometric methods, 28,30 in terms of sensitivity and linearity. Furthermore, the linearity and sensitivity of the developed sensor were comparable to some chromatographic methods and reported spectrouorometric methods without the need for the extra derivatization reactions for gabapentin detection.…”
Section: Methods Validationmentioning
confidence: 60%
“…26,27 However, these techniques have drawbacks such as the need for derivatization to create a detectable chromophore or they oen require expensive equipment, skilled operators, and time-consuming sample preparation procedures. Alternative methods like UV visible spectrophotometry [28][29][30] and spectrouorimetry [31][32][33] have been also explored for gabapentin analysis but still face limitations due to the extra derivatization step required for gabapentin detection due to the lack of chromophoric group. To overcome these challenges, there is a growing interest in developing more accessible, cost-effective, and rapid detection methods for gabapentin that do not require additional steps like derivatization.…”
An environmentally friendly N-CQDs-based fluorescence sensor for gabapentin detection is developed, with optimal detection conditions and high selectivity, accuracy, and precision in real sample analysis.
“…The limits of detection (LOD) and quantication (LOQ) were found to be 0.1600 and 0.4801 mg mL −1 , respectively. The results of this sensor transcended some reported methods for gabapentin detection, particularly the spectrophotometric methods, 28,30 in terms of sensitivity and linearity. Furthermore, the linearity and sensitivity of the developed sensor were comparable to some chromatographic methods and reported spectrouorometric methods without the need for the extra derivatization reactions for gabapentin detection.…”
Section: Methods Validationmentioning
confidence: 60%
“…26,27 However, these techniques have drawbacks such as the need for derivatization to create a detectable chromophore or they oen require expensive equipment, skilled operators, and time-consuming sample preparation procedures. Alternative methods like UV visible spectrophotometry [28][29][30] and spectrouorimetry [31][32][33] have been also explored for gabapentin analysis but still face limitations due to the extra derivatization step required for gabapentin detection due to the lack of chromophoric group. To overcome these challenges, there is a growing interest in developing more accessible, cost-effective, and rapid detection methods for gabapentin that do not require additional steps like derivatization.…”
An environmentally friendly N-CQDs-based fluorescence sensor for gabapentin detection is developed, with optimal detection conditions and high selectivity, accuracy, and precision in real sample analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.