2017
DOI: 10.1038/s41598-017-11014-5
|View full text |Cite
|
Sign up to set email alerts
|

Full-field 3D shape measurement of discontinuous specular objects by direct phase measuring deflectometry

Abstract: AbstarctWith the advent of intelligent manufacturing, phase measuring deflectometry (PMD) has been widely studied for the measurement of the three-dimensional (3D) shape of specular objects. However, existing PMDs cannot measure objects having discontinuous specular surfaces. This paper presents a new direct PMD (DPMD) method that measures the full-field 3D shape of complicated specular objects. A mathematical model is derived to directly relate an absolute phase map to depth data, instead of the gradient. Two… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
28
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 63 publications
(28 citation statements)
references
References 33 publications
0
28
0
Order By: Relevance
“…The experimental results demonstrate that the proposed calibration method can reconstruct the 3D shape of specular objects with high precision and reliability. The absolute error in the distance between neighboring steps was below 22 µm, while the value is 52 µm by using the existing calibration method [37]. Figure 12.…”
Section: Evaluation Of Resultsmentioning
confidence: 95%
See 1 more Smart Citation
“…The experimental results demonstrate that the proposed calibration method can reconstruct the 3D shape of specular objects with high precision and reliability. The absolute error in the distance between neighboring steps was below 22 µm, while the value is 52 µm by using the existing calibration method [37]. Figure 12.…”
Section: Evaluation Of Resultsmentioning
confidence: 95%
“…A novel DPMD (direct PMD) method that can obtain the full-field 3D shape of specular objects with discontinuous and/or isolated surfaces has been developed to solve the problem of measuring complex specular surfaces [36][37][38]. This method builds a direct relationship between the absolute phase and the depth information.…”
Section: Introductionmentioning
confidence: 99%
“…c) Reproduced with permission. [ 154 ] Copyright 2017, Springer Nature. d) Reproduced with permission.…”
Section: Non‐interferometric Areal Measurementmentioning
confidence: 99%
“…[ 153 ] The PMD using two LCD screens successfully measured and reconstructed multiple discontinuous surfaces sharing a monolithic substrate on the mid‐infrared spectrometer for JWST as shown in Figure 16c. [ 154 ] However, PMD has fundamental limitation of satisfying a line of sight condition, which makes it generally suitable to concave or weak convex surfaces with a large radius of curvature, e.g., grazing‐incidence X‐ray mirrors as demonstrated in the work by Huang et al. [ 147 ] The rays going through the camera pinhole reflect and diverge off the test surface in a reverse way for general convex surfaces.…”
Section: Non‐interferometric Areal Measurementmentioning
confidence: 99%
“…To solve the above problems and build a stable measurement system, a direct PMD (DPMD) system [19] has been developed to form a relationship between the phase and the depth directly without the need for a slope integration procedure. The proposed system consists of two LCD screens, one beam splitter (BS) plate and one charge-coupled device (CCD) camera.…”
Section: Introductionmentioning
confidence: 99%