2003
DOI: 10.1016/j.aca.2003.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Fully automated drug liberation apparatus for semisolid preparations based on sequential injection analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
9
0

Year Published

2004
2004
2017
2017

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 26 publications
1
9
0
Order By: Relevance
“…To test the extent of liberation of the active ingredients in semi-solid formulations, Klimundová et al coupled the SIA mountings to a liberation apparatus known as the Franz cell [150]. In this work, membranes from different materials (poly-carbonate, mixed esters of cellulose, teflon, silicon, poly-vinylidene fluoride) and different pore diameters were studied, to compare the dissolution profiles of indomethacin 1% gel.…”
Section: Automated Drug-dissolution and Drug-release Testingmentioning
confidence: 99%
“…To test the extent of liberation of the active ingredients in semi-solid formulations, Klimundová et al coupled the SIA mountings to a liberation apparatus known as the Franz cell [150]. In this work, membranes from different materials (poly-carbonate, mixed esters of cellulose, teflon, silicon, poly-vinylidene fluoride) and different pore diameters were studied, to compare the dissolution profiles of indomethacin 1% gel.…”
Section: Automated Drug-dissolution and Drug-release Testingmentioning
confidence: 99%
“…polysulphone, esters of cellulose, teflon, polycarbonate, polyvinylidene fluoride, silicone etc. [7,8].…”
Section: Introductionmentioning
confidence: 97%
“…ibuprofen [4], analgetic tablets with aspirin, phenacetin and caffeine [5], and tablets with ergotamine tartrate [6]. Firstly, the SIA system described for monitoring of release profile was suggested by our group for tests of indomethacin [7].…”
Section: Introductionmentioning
confidence: 99%
“…Several flow systems using several detection techniques have been developed for pharmaceutical analysis aiming at the continuous monitoring of dynamic processes [15][16][17][18][19]. An automated system based on the Sequential Injection Analysis (SIA) technique coupled with the Franz cell to study release rates of indomethacin from gels has been implemented [20]. A similar device has been applied to in vitro release studies of salicylic acid from semisolid dosage forms [21].…”
Section: Introductionmentioning
confidence: 99%