2020
DOI: 10.20944/preprints202007.0152.v1
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Functional Assessment of Outer and Middle Macular Layers in Multiple Sclerosis

Abstract: The involvement of macular function in its preganglionic elements, during the neurodegenerative process of multiple sclerosis (MS), is controversial. In this case-control observational and retrospective study, we assessed multifocal electroretinogram (mfERG) responses from 41 healthy Controls, 41 relapsing-remitting MS patients without optic neuritis (ON) (MS-noON Group), 47 MS patients with ON: 27 with full recovery of high-contrast best corrected visual acuity (BCVA) (MS-ON-G Group) and 20 with poor … Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 43 publications
0
7
0
Order By: Relevance
“…The involvement of macular preganglionic elements’ function, during the neurodegenerative process of MS, is controversial and there are few references on this topic. 46 …”
Section: Discussionmentioning
confidence: 99%
“…The involvement of macular preganglionic elements’ function, during the neurodegenerative process of MS, is controversial and there are few references on this topic. 46 …”
Section: Discussionmentioning
confidence: 99%
“…The mfERG was recorded by using a modified version of the Espion system (Diagnosys UK Ltd; Histon, Cambridge, UK) following the 2011 International Society for Clinical Electrophysiology of Vision (ISCEV) standards [ 25 ] and by using the same previously published method [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
“…The mfERG was recorded by using a modified version of the Espion system (Diagnosys UK Ltd; Histon, Cambridge, UK) following the 2011 International Society for Clinical Electrophysiology of Vision (ISCEV) standards [25] and by using the same previously published method [28]. Briefly, the multifocal stimulus, consisting of 61 scaled hexagons, was displayed on a highresolution, black-and-white 32 00 LCD monitor with a frame rate of 75 Hz.…”
Section: Multifocal Electroretinogram Recordingmentioning
confidence: 99%
See 1 more Smart Citation
“…In DC and DP eyes, mfERGs were recorded according to the standard ISCEV [24] and our previously published method [9,12,[25][26][27].…”
Section: Mferg Recordingsmentioning
confidence: 99%