2018
DOI: 10.1504/ijex.2018.089548
|View full text |Cite
|
Sign up to set email alerts
|

Functional exergy efficiency of an air heat recovery exchanger under varying environmental temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…It equals 0 for the evaporator as when Figure 13 shows the same temperature cases by expressing the states of heat exchangers in coenthalpies. It should be noted that in the exergy analysis of the HRE [20,45], the hot and cool working fluids of the heat exchanger are the air with the same mass flow rate, thus the results of the analysis are interpreted directly on the basis of the variation of the coenthalpies of the working fluid. When the HRE, EV and CN are assessed in an integral manner, this advantage disappears.…”
Section: Case Study -Results and Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…It equals 0 for the evaporator as when Figure 13 shows the same temperature cases by expressing the states of heat exchangers in coenthalpies. It should be noted that in the exergy analysis of the HRE [20,45], the hot and cool working fluids of the heat exchanger are the air with the same mass flow rate, thus the results of the analysis are interpreted directly on the basis of the variation of the coenthalpies of the working fluid. When the HRE, EV and CN are assessed in an integral manner, this advantage disappears.…”
Section: Case Study -Results and Discussionmentioning
confidence: 99%
“…The authors have published papers on the impact of the varying RT on the direction of the exergy flow when the heat flow is stable [20], [44]. Here we have a stationary heat transfer process that is caused by stable temperatures Th = 20°C and Tc = -20°C.…”
Section: Exergy Efficiency Of Stationary Heat Transfer Process At Varmentioning
confidence: 99%
See 1 more Smart Citation
“…It should especially be taken into account when the analyzed processes take place at near environmental temperatures. Processes that take place in AHUs have these exact characteristics [20]. However, when performing exergy research, different authors interpret environmental conditions differently, sparking scientific discussion [15].…”
Section: Introductionmentioning
confidence: 99%
“…However, when performing exergy research, different authors interpret environmental conditions differently, sparking scientific discussion [15]. In some cases, reference parameters are variables [20][21][22], and in others they are constant, e.g., the average reference temperature and pressure [23]. It is also noted that the use of design or mean outdoor temperatures for exergy analysis may lead to significant uncertainties [21].…”
Section: Introductionmentioning
confidence: 99%