Abstract: The aged eye's ability to change focus (accommodation) may be restored by replacing the hardened natural lens with a soft gel. Functionalised polysiloxane macromonomers, designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via a twostep synthesis. Prepolymers were synthesised via ring opening polymerisation (ROP) of octamethylcyclotetrasiloxane (D 4 ) and 2,4,6,8-tetramethylcyclotetrasiloxane (D 4 H ) in toluene using trifluoromethanesulfonic acid (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
46
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(50 citation statements)
references
References 53 publications
4
46
0
Order By: Relevance
“…These gels could replace conventional IOLs, and perhaps the incidence of PCO, as the gel fills the irregularly shaped lens capsule eliminating space for cell proliferation and migration. These gels also offer similar refractive index and mechanical properties to the native lens meaning the gel could allow for accommodation of focus on closer objects, which naturally degrades with age resulting in the need for reading glasses [83,85]. In previous years, however, there have been concerns over toxicity associated with leakage of unreacted monomer [85].…”
Section: Cornea and Conjunctivamentioning
confidence: 97%
See 2 more Smart Citations
“…These gels could replace conventional IOLs, and perhaps the incidence of PCO, as the gel fills the irregularly shaped lens capsule eliminating space for cell proliferation and migration. These gels also offer similar refractive index and mechanical properties to the native lens meaning the gel could allow for accommodation of focus on closer objects, which naturally degrades with age resulting in the need for reading glasses [83,85]. In previous years, however, there have been concerns over toxicity associated with leakage of unreacted monomer [85].…”
Section: Cornea and Conjunctivamentioning
confidence: 97%
“…The capsular bag is filled with a gel that sets at body temperature [83][84][85]. These gels could replace conventional IOLs, and perhaps the incidence of PCO, as the gel fills the irregularly shaped lens capsule eliminating space for cell proliferation and migration.…”
Section: Cornea and Conjunctivamentioning
confidence: 99%
See 1 more Smart Citation
“…The signals of the protons of epoxy group are detected at 2.5, 2.7, and 3.1 ppm [26]. The signal of the protons of CH 2 =C-CH 3 is detected at 1.9 ppm [27]. The signals at 0.5, 1.6, and 4.0 ppm are assigned to the protons of -COO-CH 2 -CH 2 -CH 2 -, -COO-CH 2 -CH 2 -, and -COO-CH 2 -, respectively [28].…”
mentioning
confidence: 99%
“…Silicone ( poly(dimethylsiloxane), PDMS) artefacts are often employed for biomedical use in the form of medical devices 1 such as intraocular lenses, 2 urinary catheters 3 and breast implants, 4 but also microfluidic constructs; 5 in their application they are often in contact with biological fluids, and the ensuing surface adsorption of proteins may lead to undesired outcomes, which in vivo can take the form of foreign body capsular reactions or of phenomena of platelet adhesion/activation. 6,7 Another disadvantage of PDMS surfaces is the possibility of bacterial attachment, leading to the formation of biofilms, which are among the first promoters of chronic infections.…”
Section: Introductionmentioning