2004
DOI: 10.1007/978-3-540-44490-9_8
|View full text |Cite
|
Sign up to set email alerts
|

Gamma-Rayand Conversion-Electron Spectroscopyof Exotic Heavy Nuclei

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2004
2004
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 54 publications
0
3
0
Order By: Relevance
“…Because of the experiments proposed for DESPEC and the two operational modes of the Super-FRS: achromatic or monochromatic, the ion implantation in the AIDA plane will not be homogeneous. To evaluate the basic benefits for the different geometries, the most relevant parameters are the peak efficiency and the P/T ratio, therefore, mean values of these parameters ((ε p ) and (P/T )) have been calculated in a surface of 22*6 cm 2 of the AIDA central slide since in this region ions will be implanted with higher probability ( Table 2. 5). Other important parameters that should be considered in the choice of the 2.5 Performance study of the DESPEC Ge array 41 array geometry are the number of electronic channels and the amount of Ge employed in the design, because they are directly related to the cost of the system.…”
Section: Performance Study Of the Despec Ge Array 35mentioning
confidence: 99%
See 2 more Smart Citations
“…Because of the experiments proposed for DESPEC and the two operational modes of the Super-FRS: achromatic or monochromatic, the ion implantation in the AIDA plane will not be homogeneous. To evaluate the basic benefits for the different geometries, the most relevant parameters are the peak efficiency and the P/T ratio, therefore, mean values of these parameters ((ε p ) and (P/T )) have been calculated in a surface of 22*6 cm 2 of the AIDA central slide since in this region ions will be implanted with higher probability ( Table 2. 5). Other important parameters that should be considered in the choice of the 2.5 Performance study of the DESPEC Ge array 41 array geometry are the number of electronic channels and the amount of Ge employed in the design, because they are directly related to the cost of the system.…”
Section: Performance Study Of the Despec Ge Array 35mentioning
confidence: 99%
“…With this method a P/T of 50% can be obtained. Figure 1.1: a) Anti-Compton detector surrounding the Ge detector with the aim of suppress the partially absorbed events in the spectra; b) detector composed by different Ge crystals that allows to add the signals; c) segmented detector that allows the reconstruction of the individual trajectory of γ rays [5].…”
Section: Introduction To the High Resolution γ-Ray Spectroscopymentioning
confidence: 99%
See 1 more Smart Citation