1989
DOI: 10.1021/ac00192a019
|View full text |Cite
|
Sign up to set email alerts
|

Gas chromatographic sample introduction into the collision cell of a triple quadrupole mass spectrometer for mass-selection of reactant ions for charge exchange and chemical ionization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

1989
1989
1998
1998

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 21 publications
0
4
0
Order By: Relevance
“…However, this severely limits the range of compounds that can be analyzed in a single chromatogram (14). A second approach is to program the flow rate of the carrier gas instead of the temperature (12,(14)(15)(16)(17)(18)(19). Due to the high permeability of open tubular columns, the reequilibration time is relatively short, but the range of boiling…”
mentioning
confidence: 99%
“…However, this severely limits the range of compounds that can be analyzed in a single chromatogram (14). A second approach is to program the flow rate of the carrier gas instead of the temperature (12,(14)(15)(16)(17)(18)(19). Due to the high permeability of open tubular columns, the reequilibration time is relatively short, but the range of boiling…”
mentioning
confidence: 99%
“…200-ng quantities reported here provide high signalto-noise ratios for those analytes that react. Previous studies of charge-exchange reactions in the collision cell have yielded full-scan detection limits of 100 pg [12].…”
Section: Discussionmentioning
confidence: 99%
“…The reaction of pyridine with various electrophiles was studied in the collision cell of a Finnigan MAT TSQ 70 triple quadrupole mass spectrometer. The concepts, instrumentation, and performance of GC introduction into the second quadrupole (collision cell, Q2) of a tandem mass spectrometer were described previously [12]. Pyridine was introduced continuously into the ion source by a Granville Phillips fine-metering valve, and the analytes were introduced into the collision cell by means of a J&W Scientific 6m DB-5 (0.178 mm i.d., 0.4 IJ.m film thickness) capillary column.…”
Section: Reactions In the Collision Cellmentioning
confidence: 99%
“…Hail et a1. 22 have interfaced a gas chromatograph to the collision cell of a triple quadrupole instrument and have shown that the aromatic components of a test mixture can be selectively ionized as they elute from the gas chromatograph by using charge exchange from mass-selected [c6H6] + * (benzene) ions. S~h r O d e r~~ also has demonstrated the ionization of toluene in a quadrupole cell by charge exchange with mass-selected Ar+' ions.…”
Section: Introductionmentioning
confidence: 99%