Gate Drive Controller for Low Voltage DC Hybrid Circuit Breaker

Abstract: With the advent of direct current (DC) loads such as LED lighting, IT equipment, electric vehicles, and DC powers generated from renewable energy sources, low voltage DC (LVDC) distribution system is becoming a hot issue. One of the hurdles in the LVDC distribution system is arc flash at the contact points that occurs during the circuit is opening. Unlike alternating current, direct current has no zero points and sustains constantly. Therefore, there is a risk of electric fire due to continuous generating arcs… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…Also, compare the same operator types but for different breakers; the curves should have similar signature and comparable time characteristics. If the trip time is good but close time is slow, the tail spring is out of adjustment and may be masking a bearing problem [16]- [20].…”
Section: Methodsmentioning
confidence: 99%
“…Also, compare the same operator types but for different breakers; the curves should have similar signature and comparable time characteristics. If the trip time is good but close time is slow, the tail spring is out of adjustment and may be masking a bearing problem [16]- [20].…”
Section: Methodsmentioning
confidence: 99%
“…Another fundamental feature that characterizes IDD is its repeatability of operation and long-term reliability (provided that the correct parameters of all its components are determined). The above advantages of the IDD resulted in its taking over from other types of drives (e.g., spring ones) in many circuit breakers, especially in the so-called hybrid circuit breakers (Figure 1b) of both DC [20][21][22][23][24][25][26] and AC used in synchronous switchingoff [27][28][29][30][31][32][33]. The interest of the authors in the study of this type of drive is mainly related to their application in the class of circuit breakers considered [30,[32][33][34][35][36][37][38][39][40][41].…”
Section: Inductive Dynamic Drive (Idd)mentioning
confidence: 99%
“…In addition, the breaking time of a mechanical circuit breaker is generally about 30-100 ms [15]. Therefore, it has been proposed a reverse current injection method [16][17][18], a current conversion method [19], a reverse voltage generation method [6,8,10,12,19], and a divergence oscillation method to compensate for the limitations of the mechanical circuit breaker. In the reverse current injection method, the reverse current [I reverse > I f ault ] is injected and cut off by discharging through a pre-charged capacitor and reactor.…”
Section: Introductionmentioning
confidence: 99%