2006
DOI: 10.1016/s1001-8042(06)60051-1
|View full text |Cite
|
Sign up to set email alerts
|

Geant4 used in medical physics and hadrontherapy technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…In order to test the accuracy of the calculations in order to find the appropriate doses of protons and carbon beams in the water phantom, the Bragg curves of 80,100, 120 and 140 MeV energy proton beams and 1.6, 2.4 and 3.0 GeV energy carbon beams normalized to the maximum dose in the water phantom were compared with the literature [13][14][15][16][17][18][19][20][21][22][23]. By comparison, an average difference of 3.37% for the two particles was observed is generally not significant and is within acceptable limits (<5%) in medical physics.…”
Section: Resultsmentioning
confidence: 99%
“…In order to test the accuracy of the calculations in order to find the appropriate doses of protons and carbon beams in the water phantom, the Bragg curves of 80,100, 120 and 140 MeV energy proton beams and 1.6, 2.4 and 3.0 GeV energy carbon beams normalized to the maximum dose in the water phantom were compared with the literature [13][14][15][16][17][18][19][20][21][22][23]. By comparison, an average difference of 3.37% for the two particles was observed is generally not significant and is within acceptable limits (<5%) in medical physics.…”
Section: Resultsmentioning
confidence: 99%
“…GEANT4 19 is a promising Monte Carlo (MC) simulation code and has been widely applied in dose calculation for medical physics and radiation protection. [20][21][22][23][24][25][26][27] In this study, GEANT4 (version 4.10.1.p02) was adopted to simulate the proton transportation under magnetic fields. Three types of geometry configurations were constructed and investigated using GEANT4.…”
Section: Methodsmentioning
confidence: 99%
“…The presented investigation was based on the Monte Carlo computer simulations with the use of the GEANT4 software in the version 4.9.3. The GEANT4 code is recommended by many scientists for application in proton and other kinds of radiotherapy 11,6,[12][13][14] because it provides all physical processes occurring during the emission of proton therapeutic beams, based on extensive data bases of experimental parameters, cross-section, etc. The majority of physical process models is based on experimental data bases which makes it possible to obtain very accurate results.…”
Section: Methodsmentioning
confidence: 99%