1975
DOI: 10.1109/t-pas.1975.32045
|View full text |Cite
|
Sign up to set email alerts
|

General expression for positive switching impulse strength valid up to extra long air gaps

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

1983
1983
2020
2020

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(15 citation statements)
references
References 4 publications
0
15
0
Order By: Relevance
“…Several equations were proposed to formulate the relationship between the critical flashover voltages (CFOs), and the strike distances for SI voltages [1,[17][18][19]. Equation (1) was proposed in [17] to approximate the critical positive flashover voltage for SI voltages under dry test conditions.…”
Section: Switching Impulse Voltage Testsmentioning
confidence: 99%
See 1 more Smart Citation
“…Several equations were proposed to formulate the relationship between the critical flashover voltages (CFOs), and the strike distances for SI voltages [1,[17][18][19]. Equation (1) was proposed in [17] to approximate the critical positive flashover voltage for SI voltages under dry test conditions.…”
Section: Switching Impulse Voltage Testsmentioning
confidence: 99%
“…k g is recommended to be 1.20 for the conductor-window electrode system such as vertical and V-string configurations. Another equation was proposed by [18] for SI voltages, but for the critical wave fronts, and for the gap spacing up to 12 m.…”
Section: Switching Impulse Voltage Testsmentioning
confidence: 99%
“…Then standard SI tests are done with Tp = 250 Ils. Gallet et al introduced later an alternate equation to calculate USOO/o Sl for a critical time to peak with respect to a given gap spacing [7].…”
Section: Gap Factor Conceptmentioning
confidence: 99%
“…This section treats the breakdown characteristics of various long air gap structures for switching impulse by assuming UHV-class equipment. Figure 4 [14] summarizes the past and recent results of breakdown characteristics of a long air gap of rod-plane electrodes, which is a general fundamental model, under dry condition [9][10][11][12][13][14]. This shows the measurement results of the 50% breakdown voltages using switching impulse waveforms of positive polarity, which is severer in terms of insulation, with the Tp and gap length as parameters.…”
Section: Breakdown Characteristics Of Long Air Gap Insulation For Swimentioning
confidence: 99%
“…Firstly for this purpose, the actual records of switching overvoltage waveforms generated in UHV systems in Japan and China are investigated [2][3][4][5][6][7][8]. Secondly, the insulation characteristics of the long air gap [9][10][11][12][13][14][15][16] and the internal insulation, such as SF 6 gas and oil-paper insulation [17][18][19][20][21][22][23][24][25], for switching impulses with a long Tp are investigated. Based on these results, a study is conducted on the switching impulse test waveform suitable for UHV system equipment.…”
Section: Introductionmentioning
confidence: 99%