2012
DOI: 10.1109/tie.2011.2167117
|View full text |Cite
|
Sign up to set email alerts
|

Generalized Design of High Performance Shunt Active Power Filter With Output LCL Filter

Abstract: This paper concentrates on the design, control, and implementation of an LCL-filter-based shunt active power filter (SAPF), which can effectively compensate for harmonic currents produced by nonlinear loads in a three-phase three-wire power system. With an LCL filter added at its output, the proposed SAPF offers superior switching harmonic suppression using much reduced passive filtering elements. Its output currents thus have high slew rate for tracking the targeted reference closely. Smaller inductance of th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
253
1
5

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 502 publications
(260 citation statements)
references
References 28 publications
1
253
1
5
Order By: Relevance
“…Hence, many publications [48-56, 60-74, 80-81, 129] have been reviewed on three-phase power quality conditioners suitable for railway traction with many control strategies. In the three-phase power quality conditioners, active filters can be connected in series, shunt [48][49][50][51][52][53][54][55][56][57], combination of series and shunt called unique power quality conditioners [80][81] and passive filters combined with active filters [60][61][62][63][64][65][66][67][68][69][70][71][72][73][74]129] are being used.…”
Section: State Of the Artmentioning
confidence: 99%
See 3 more Smart Citations
“…Hence, many publications [48-56, 60-74, 80-81, 129] have been reviewed on three-phase power quality conditioners suitable for railway traction with many control strategies. In the three-phase power quality conditioners, active filters can be connected in series, shunt [48][49][50][51][52][53][54][55][56][57], combination of series and shunt called unique power quality conditioners [80][81] and passive filters combined with active filters [60][61][62][63][64][65][66][67][68][69][70][71][72][73][74]129] are being used.…”
Section: State Of the Artmentioning
confidence: 99%
“…Power quality conditioners for railway traction based on topology are classified as passive filter [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33], active filter in series [50,56] shunt [37,38,40,43,46,47,49,51,52,54,55,108] and combination of active filter and passive filters connected in shunt known as hybrid filters [36,43,60,62,63,65,66,67,69,70,71,73,74,107,119], half bridge [112], TCR with fixed capacitors [108,129] TCR with passive …”
Section: Classification Based On Topologymentioning
confidence: 99%
See 2 more Smart Citations
“…Also current controller requires relatively faster sampling rate and computation update rate, typically in microseconds, to sustain the closed-loop bandwidth, to increase the accuracy in sensing the voltage and current, parameter estimation and to provide highfrequency pulse width modulation. The processing speed needed to deal with these tasks is in the order of microseconds, which makes it difficult to implement within a DSPs or microcontroller software computation environment [14][15].…”
Section: Introductionmentioning
confidence: 99%