Abstract: Background Three-dimensional (3D) printing techniques have been used to produce anatomical models and surgical guiding instruments in orthopaedic surgery. The geometric accuracy of the 3D printed replica may affect surgical planning. This study assessed the geometric accuracy of an acrylonitrile butadiene styrene (ABS) canine tibia model printed using fused deposition modelling (FDM) and evaluated its morphological change after hydrogen peroxide (H2O2) gas plasma sterilisation. The tibias of si… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 38 publications
1
2
0
Order By: Relevance
“…According to Toro et al, vaporized hydrogen peroxide sterilization provides dimensional stability for sterilized ABS-3D printed elements [ 223 ]. The same was reported by other authors [ 224 , 225 ]. PEEK implants are known to retain their mechanical properties after multiple steam sterilization cycles [ 226 , 227 ].…”
Section: Sterilizationsupporting
confidence: 91%
“…According to Toro et al, vaporized hydrogen peroxide sterilization provides dimensional stability for sterilized ABS-3D printed elements [ 223 ]. The same was reported by other authors [ 224 , 225 ]. PEEK implants are known to retain their mechanical properties after multiple steam sterilization cycles [ 226 , 227 ].…”
Section: Sterilizationsupporting
confidence: 91%
“…Multi-colour extrusion FDM has been used as a low-cost 3D printing method for anatomical prostate cancer models [53]. An acrylonitrile butadiene styrene (ABS) canine tibia model [54] and complete dentures have been fabricated by FDM [55].…”
Section: Introductionmentioning
confidence: 99%
“…As Oth et al (2019) point out, chemical sterilization such as peroxide plasma ethylene oxide is a suitable method for genioplasty cutting guides made of PLA and PETG (polyethylene terephthalate glycol), which both suffer from deformation in the sub-millimeter range [ 14 ]. In addition, other studies name high costs, toxic hazardous residues, and in-contrast deformations on the sterilized product in short- and long-term sterilization [ 9 , 12 , 13 , 14 , 15 , 16 , 17 , 18 , 19 ]; One of the most frequently used methods is autoclaving. Its roots are in the 17th century, when Denis Papin experimented with his “Steam Digester” [ 20 ].…”
Section: Introductionmentioning
confidence: 99%