The high cost of biofabricated titanium mesh plates can make them out of reach for hospitals in low-income countries. To increase the availability of cranioplasty, the authors of this work investigated the production of polymer-based endoprostheses. Recently, cheap, popular desktop 3D printers have generated sufficient opportunities to provide patients with on-demand and on-site help. This study also examines the technologies of 3D printing, including SLM, SLS, FFF, DLP, and SLA. The authors focused their interest on the materials in fabrication, which include PLA, ABS, PET-G, PEEK, and PMMA. Three-dimensional printed prostheses are modeled using widely available CAD software with the help of patient-specific DICOM files. Even though the topic is insufficiently researched, it can be perceived as a relatively safe procedure with a minimal complication rate. There have also been some initial studies on the costs and legal regulations. Early case studies provide information on dozens of patients living with self-made prostheses and who are experiencing significant improvements in their quality of life. Budget 3D-printed endoprostheses are reliable and are reported to be significantly cheaper than the popular counterparts manufactured from polypropylene polyester.
Hydroxyapatite possesses desirable properties as a scaffold in tissue engineering: it is biocompatible at a site of implantation, and it is degradable to non-toxic products. Moreover, its porosity enables infiltration of cells, nutrients and waste products. The outcome of hydroxyapatite implantation highly depends on the extent of the host immune response. Authors emphasise major roles of the chemical, morphological and physical properties of the surface of biomaterial used. A number of techniques have been applied to transform the theoretical osteoconductive features of HAp into spinal fusion systems—from integration of HAp with autograft to synthetic intervertebral implants. The most popular uses of HAp in spine surgery include implants (ACDF), bone grafts in posterolateral lumbar fusion and transpedicular screws coating. In the past, autologous bone graft has been used as an intervertebral cage in ACDF. Due to the morbidity related to autograft harvesting from the iliac bone, a synthetic cage with osteoconductive material such as hydroxyapatite seems to be a good alternative. Regarding posterolateral lumbar fusion, it requires the graft to induce new bone growth and reinforce fusion between the vertebrae. Hydroxyapatite formulations have shown good results in that field. Moreover, the HAp coating has proven to be an efficient method of increasing screw fixation strength. It can decrease the risk of complications such as screw loosening after pedicle screw fixation in osteoporotic patients. The purpose of this literature review is to describe in vivo reaction to HAp implants and to summarise its current application in spine surgery.
Spinal Cord Injury (SCI) is a common neurological disorder with devastating psychical and psychosocial sequelae. The majority of patients after SCI suffer from permanent disability caused by motor dysfunction, impaired sensation, neuropathic pain, spasticity as well as urinary complications, and a small number of patients experience a complete recovery. Current standard treatment modalities of the SCI aim to prevent secondary injury and provide limited recovery of lost neurological functions. Stem Cell Therapy (SCT) represents an emerging treatment approach using the differentiation, paracrine, and self-renewal capabilities of stem cells to regenerate the injured spinal cord. To date, multipotent stem cells including mesenchymal stem cells (MSCs), neural stem cells (NSCs), and hematopoietic stem cells (HSCs) represent the most investigated types of stem cells for the treatment of SCI in preclinical and clinical studies. The microenvironment of SCI has a significant impact on the survival, proliferation, and differentiation of transplanted stem cells. Therefore, a deep understanding of the pathophysiology of SCI and molecular mechanisms through which stem cells act may help improve the treatment efficacy of SCT and find new therapeutic approaches such as stem-cell-derived exosomes, gene-modified stem cells, scaffolds, and nanomaterials. In this literature review, the pathogenesis of SCI and molecular mechanisms of action of multipotent stem cells including MSCs, NSCs, and HSCs are comprehensively described. Moreover, the clinical efficacy of multipotent stem cells in SCI treatment, an optimal protocol of stem cell administration, and recent therapeutic approaches based on or combined with SCT are also discussed.
Over the last decade, pedicle fixation systems have evolved and modifications in spinal fusion techniques have been developed to increase fusion rates and improve clinical outcomes after lumbar interbody fusion (LIF). Regarding materials used for screw and rod manufacturing, metals, especially titanium alloys, are the most popular resources. In the case of pedicle screws, that biomaterial can be also doped with hydroxyapatite, CaP, ECM, or tantalum. Other materials used for rod fabrication include cobalt–chromium alloys and nitinol (nickel–titanium alloy). In terms of mechanical properties, the ideal implant used in LIF should have high tensile and fatigue strength, Young’s modulus similar to that of the bone, and should be 100% resistant to corrosion to avoid mechanical failures. On the other hand, a comprehensive understanding of cellular and molecular pathways is essential to identify preferable characteristics of implanted biomaterial to obtain fusion and avoid implant loosening. Implanted material elicits a biological response driven by immune cells at the site of insertion. These reactions are subdivided into innate (primary cellular response with no previous exposure) and adaptive (a specific type of reaction induced after earlier exposure to the antigen) and are responsible for wound healing, fusion, and also adverse reactions, i.e., hypersensitivity. The main purposes of this literature review are to summarize the physical and mechanical properties of metal alloys used for spinal instrumentation in LIF which include fatigue strength, Young’s modulus, and corrosion resistance. Moreover, we also focused on describing biological response after their implantation into the human body. Our review paper is mainly focused on titanium, cobalt–chromium, nickel–titanium (nitinol), and stainless steel alloys.
Neuropathic pain is generally defined as a non-physiological pain experience caused by damage to the nervous system. It can occur spontaneously, as a reaction to a given stimulus, or independently of its action, leading to unusual pain sensations usually referred to as firing, burning or throbbing. In the course of spine disorders, pain symptoms commonly occur. According to available epidemiological studies, a neuropathic component of pain is often present in patients with spinal diseases, with a frequency ranging from 36% to 55% of patients. Distinguishing between chronic nociceptive pain and neuropathic pain very often remains a challenge. Consequently, neuropathic pain is often underdiagnosed in patients with spinal diseases. In reference to current guidelines for the treatment of neuropathic pain, gabapentin, serotonin and norepinephrine reuptake inhibitors and tricyclic antidepressants constitute first-line therapeutic agents. However, long-term pharmacologic treatment often leads to developing tolerance and resistance to used medications. Therefore, in recent years, a plethora of therapeutic methods for neuropathic pain have been developed and investigated to improve clinical outcomes. In this review, we briefly summarized current knowledge about the pathophysiology and diagnosis of neuropathic pain. Moreover, we described the most effective treatment approaches for neuropathic pain and discussed their relevance in the treatment of spinal pain.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.