2012
DOI: 10.1016/j.talanta.2012.02.057
|View full text |Cite
|
Sign up to set email alerts
|

Gold–silver-nanoclusters having cholic acid imprinted nanoshell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 44 publications
0
13
0
Order By: Relevance
“…The frequency shift for each concentration (0.01-1000 μM) of cholic acid was calculated using the equation ΔF = F 0 -F 1 and the evaluation was performed in triplicate. After each analysis, the desorption process was applied using 2 M sodium hydroxide/ tetrahydrofuran (NaOH/THF) (3:1, v/v) [3]. After desorption step, the cholic acid imprinted QCM nanosensor was washed with deionized water.…”
Section: Monitoring Of the Response Of Cholic Acid Imprinted Qcm Nanomentioning
confidence: 99%
See 1 more Smart Citation
“…The frequency shift for each concentration (0.01-1000 μM) of cholic acid was calculated using the equation ΔF = F 0 -F 1 and the evaluation was performed in triplicate. After each analysis, the desorption process was applied using 2 M sodium hydroxide/ tetrahydrofuran (NaOH/THF) (3:1, v/v) [3]. After desorption step, the cholic acid imprinted QCM nanosensor was washed with deionized water.…”
Section: Monitoring Of the Response Of Cholic Acid Imprinted Qcm Nanomentioning
confidence: 99%
“…Hence, the quantification of bile acids in body fluids (such as plasma and urine) is an important tool for the diagnosis of hepatobiliary diseases. Cholic acid as well as its derivatives is a major component of bile acids [3].…”
Section: Introductionmentioning
confidence: 99%
“…The molecularly imprinted polymers (MIPs) are durable and steady synthetic receivers for the analyte of interest. The production of MIPs to perceive specific compounds via quartz crystal microbalance (QCM), which is extremely sensitive to the nanogram level of mass changing weighted down the surface of the QCM electrode, has been achieved in recent years [21][22][23][24][25][26] and the procedure is rapid, low cost, easy to use, highly specific and selective.…”
Section: Introductionmentioning
confidence: 99%
“…[1,2] Usually in clinic, evaluation of bile acids concentration in body has been employed to diagnose hepatitis, gallstone and other diseases in liver. [4,5] Therefore, it is very important for the determination of bile acids in body fluids (such as serum and urine) for the diagnosis of hepatobiliary diseases. However, in hepatobiliary and intestinal diseases, because the hepatic synthesis and clearance of bile acids and their intestinal absorption are disturbed, the concentration of bile acids is elevated by two or three fold for individuals.…”
Section: Introductionmentioning
confidence: 99%