2011
DOI: 10.1007/978-3-642-20338-1_13
|View full text |Cite
|
Sign up to set email alerts
|

GPS Metrology: Bringing Traceable Scale to a Local Crustal Deformation GPS Network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 4 publications
0
10
0
Order By: Relevance
“…We started our research in submillimetric GNSS-based length determination, first analyzing the inner consistency of results [11], then with a first comparison with respect to a value obtained by absolute-scale transfer from the Nummela baseline with a Mekometer ME5000 [12], a type of comparison that has also been done by other authors (e.g. [13]). We explored different strategies to mitigate noise, especially multipath [12,14,15] and finally came with a working scheme for a GBDM [16].…”
Section: Introductionmentioning
confidence: 99%
“…We started our research in submillimetric GNSS-based length determination, first analyzing the inner consistency of results [11], then with a first comparison with respect to a value obtained by absolute-scale transfer from the Nummela baseline with a Mekometer ME5000 [12], a type of comparison that has also been done by other authors (e.g. [13]). We explored different strategies to mitigate noise, especially multipath [12,14,15] and finally came with a working scheme for a GBDM [16].…”
Section: Introductionmentioning
confidence: 99%
“…By building the seventh pillar additional 6 baselines in the test field were created. The triangle-shaped test field provides more possibilities for testing of surveying instruments [4,5,6]. Calibration of the Kyviškės Baseline is done on the regular basis at approximate 5 years interval.…”
Section: Conversion From the Calibration Baseline To The Test Fieldmentioning
confidence: 99%
“…Kyviskes Calibration Baseline was established by the Institute of Geodesy, VGTU in 1996 for the calibration of EDM instruments [1]. Finnish Geodetic Institute together with Institute of Geodesy, VGTU are measuring Kyviskes Calibration Baseline on a regular basis in [5][6][7] year cycles. The same Kern Mekometer ME5000 EDM instrument was used for all measurements performed.…”
Section: Introduction Kyviskes Calibration Baselinementioning
confidence: 99%
“…This is also the proposal followed in the preceding study of Koivula et al (2012). However, their distance determination study is only based on four campaigns of two 24-h sessions of GPS data.…”
Section: Initial Assumptionsmentioning
confidence: 99%