2015
DOI: 10.1016/j.bios.2015.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Grafted-double walled carbon nanotubes as electrochemical platforms for immobilization of antibodies using a metallic-complex chelating polymer: Application to the determination of adiponectin cytokine in serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 53 publications
(28 citation statements)
references
References 28 publications
0
28
0
Order By: Relevance
“…The amount of Mix&Go used was that optimized previously in our group (Ojeda et al, 2015) and, in these studies, conventional HRP-Strep was used to label the detection antibody since the effect of the other variables should not depend on the type of label employed.…”
Section: Optimization Of the Experimental Variables Involved In The Pmentioning
confidence: 99%
See 2 more Smart Citations
“…The amount of Mix&Go used was that optimized previously in our group (Ojeda et al, 2015) and, in these studies, conventional HRP-Strep was used to label the detection antibody since the effect of the other variables should not depend on the type of label employed.…”
Section: Optimization Of the Experimental Variables Involved In The Pmentioning
confidence: 99%
“…This polymer uses ligands to bind Fc domains that mimic those binding domains from proteins A and G (Ooi et al, 2014), and can also interact strongly with electron donating moieties such as dissociated carboxyl groups. Therefore, combination of HOOC-MBs with the use of Mix&Go for antibody immobilization resulted in a convenient methodology to be applied as a general route for the preparation of electrochemical immunosensors (Ojeda et al, 2015). Capture antibodies immobilization was followed by a blocking step with ethanolamine (step 2) and the implementation of a sandwich-type immunoassay employing a biotinylated secondary antibody and poly-HRP-Strept for signal amplification (step 3).…”
Section: Analysis Of Spiked Urinementioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, screen-printed electrodes (SPEs) are appropriate platforms for the immobilization of biomolecules, e.g. nucleic acid (Das et al 2014), enzymes (Henao-Escobar et al 2016) or antibodies (Ojeda et al 2015) onto the underlying working electrode surface in order to obtain a sensitive, selective, disposable electrochemical biosensor. SPE platforms are mostly based on carbon materials in which the nature, structural and physic-chemical properties of the carbonaceous materials have paid significant attention to the performance of the electrochemical (bio)sensors.…”
Section: Introductionmentioning
confidence: 99%
“…The histidine cluster His 433-X-His 435 was found to be surface accessible to affinity binding using these metals without the need for recombinant tags. Muir et al 124 prepared metal coordinating polymer substrates and screened a large range of transition metals to ) to achieve oriented immobilization of native anti-adiponectin antibody on carboxyphenyl multiwalled carbon nanotubes 125 and graphene oxide-carboxymethyl cellulose hybrid. 126 Recently, Welch et al 127 employed the chromium complex, [Cr(OH) 6 ] 3À , buffered with ethylenediamine as a wet chemical modification to ten commercial microtiter plates, postproduction, to improve antibody immobilization and ELISA performance.…”
Section: Metal Affinitymentioning
confidence: 99%