A novel magnetoimmunosensor design for interleukin-6 (IL-6) which involved the covalent immobilization of anti-IL-6 antibodies onto carboxyl-functionalized magnetic microparticles and a sandwich-type immunoassay with signal amplification using poly-HRP-streptavidin conjugates is reported. All the variables concerning the preparation and the electroanalytical performance of the immunosensor were optimized. The use of poly-HRP-strept conjugates as enzymatic labels instead of conventional HRP-strept allowed enhanced signal-to-blank current ratios to be obtained. A linear calibration plot between the measured steady-state current and the log of IL-6 concentration was achieved in the 1.75 to 500 pg/mL range, which was not feasible when using HRP-strep as label. A limit of detection of 0.39 pg/mL IL-6 was obtained. The anti-IL-6-MB conjugates exhibited an excellent storage stability providing amperometric responses with no significant loss during at least 36 days. The magnetoimmunosensor showed also an excellent selectivity against potentially interfering substances. The immunosensor was used to determine IL-6 in urine samples spiked at three different concentration levels with clinical relevance. Moreover, IL-6 was measured in three different saliva samples corresponding to a periodontitis patient, a smoker volunteer, and a non-smoker volunteer. The obtained results were statistically in agreement with those provided by a commercial ELISA kit.
This work reports for the first time an electrochemical immunosensor for the determination of adrenocorticotropin hormone (ACTH). The immunoelectrode design involves the use of amino phenylboronic acid for the oriented immobilization of anti-ACTH antibodies onto screen-printed carbon modified electrode surfaces. A competitive immunoassay between the antigen and the biotinylated hormone for the binding sites of the immobilized antibody was performed. The electroanalytical response was generated by using alkaline phosphatase-labelled streptavidin and 1-naphtyl phosphate as the enzyme substrate. The electrochemical oxidation of the enzyme reaction product, 1-naphtol, measured by differential pulse voltammetry was employed to monitor the affinity reaction. Under the optimized working conditions, an extremely low detection limit of 18 pg/L was obtained. Cross-reactivity was evaluated against other hormones (cortisol, estradiol, testosterone, progesterone, hGH and prolactin) and the obtained results demonstrated an excellent selectivity. The developed immunosensor was applied to a human serum sample containing a certified amount of ACTH with good results.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.