2000
DOI: 10.1016/s0168-1699(00)00074-0
|View full text |Cite
|
Sign up to set email alerts
|

Grain flow measurements with X-ray techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
12
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(12 citation statements)
references
References 3 publications
0
12
0
Order By: Relevance
“…Furthermore, the percentage of the opening area of the auger available to the paddle of interest during these times is equivalent. It follows that 4) which simplifies to .5) Noting that the elapsed time between t 3 and t 1 is equivalent to d V , the mass deposited onto a single paddle for any arbitrary cross-sectional area opening of the auger is described by .6) Appendix C Paddle filling process during circular motion for an arbitrary cross sectional auger opening…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, the percentage of the opening area of the auger available to the paddle of interest during these times is equivalent. It follows that 4) which simplifies to .5) Noting that the elapsed time between t 3 and t 1 is equivalent to d V , the mass deposited onto a single paddle for any arbitrary cross-sectional area opening of the auger is described by .6) Appendix C Paddle filling process during circular motion for an arbitrary cross sectional auger opening…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, the percentage of the opening area of the auger available to the paddle of interest during these times is equivalent. It follows that 4) which simplifies to…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are mainly four types of grain flow sensor: impact-type [1], ray-type [2], volume-type [3], and weight-type [4]. Most commercial yield monitoring systems rely on impact-type for security, reliability, and simple structure.…”
Section: Introductionmentioning
confidence: 99%
“…Mass flow measurement principles include a plate impact sensor , torque sensors mounted on the elevator paddles ), a torque sensor mounted on the clean grain elevator drive shaft (Zandonadi et al 2008), a diaphragm impact sensor (Schrock et al 1999), a pivoted-auger-fed device (Wagner 1998), and weighing of the clean grain auger (Colvin 1990). Indirect methods encompass a capacitive sensor (Borgelt 1993), an ultrasonic sensor (Borgelt 1993), and X-ray measurement principles (Arslan et al 2000).…”
Section: Introductionmentioning
confidence: 99%