2022
DOI: 10.1016/j.apsusc.2022.154430
|View full text |Cite
|
Sign up to set email alerts
|

Graphene-anchored conductive polymer aerogel composite for the electrocatalytic detection of hydrogen peroxide and bisphenol A

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 34 publications
0
6
0
Order By: Relevance
“…Figure S4 shows the response current values retained from the original responses for both UA and BPA. After four weeks, the electrode demonstrated excellent stability, maintaining 93.9% and 95.8% of the initial responses for UA and BPA, respectively, indicating that good long-term stability could be obtained from the electrode for the detection of UA and BPA [13].…”
Section: Calibration Data Limit Of Detection Reproducibility Repeatab...mentioning
confidence: 93%
See 1 more Smart Citation
“…Figure S4 shows the response current values retained from the original responses for both UA and BPA. After four weeks, the electrode demonstrated excellent stability, maintaining 93.9% and 95.8% of the initial responses for UA and BPA, respectively, indicating that good long-term stability could be obtained from the electrode for the detection of UA and BPA [13].…”
Section: Calibration Data Limit Of Detection Reproducibility Repeatab...mentioning
confidence: 93%
“…Yet, the addition of layered double hydroxides (LDH) shows better performance in electrocatalysis and provides better detection of analytes by overcoming the poor response of analytes. LDH can obviously be an attractive material for modified electrodes in electrochemical analysis [12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…Among all four electrodes, the p(APT-rGO) aerogel showed the maximum current response, which is attributed to its extensive surface area, effective conductivity, and the interaction of charges with pAPT. 75 Zheng and Andou briefly reviewed on the detection and removal of the BPA endocrine disruptor using graphene-based materials. 10 Gallic acid, a phenolic compound, is harmful for living bodies, therefore its detection and removal from wastewater is necessary.…”
Section: Reaction Chemistry and Engineering Reviewmentioning
confidence: 99%
“…18 In another report, a similar endocrine disruptor was electrochemically detected by an rGO–polyterthiophene composite ( p (APT–rGO)) aerogel based sensor with an improved detection limit. 75 Fig. 6d shows the CV responses for BPA, dopamine (DA), ascorbic acid (AA), uric acid (UA), phenol (Ph), p -nitrophenol ( p -NP), o -cresol ( o -Cr) and aminophenol (AP) and the inset of Fig.…”
Section: Emerging Pollutants and Their Detection Using Graphene Aerogelsmentioning
confidence: 99%
“…GAs composites are good candidates for the development of biosensors due to their excellent properties, such as a rich pore structure, large surface area, high conductivity, low density, and good biocompatibility [22,23]. In this study, a GAs-AuNPs-modified electrode was obtained and characterized by different characterization techniques.…”
Section: Characterization Of Morphology and Composition Of Gas-aunpsmentioning
confidence: 99%