2018
DOI: 10.11591/ijece.v8i6.pp4047-4059
|View full text |Cite
|
Sign up to set email alerts
|

Grid Connected Distributed Generation System with High Voltage Gain Cascaded DC-DC Converter Fed Asymmetric Multilevel Inverter Topology

Abstract: The paper presents distributed generation (DG) system in grid connected mode of operation with asymmetric multi-level inverter (AMLI) topology. Cascaded type DC-DC converter is employed to feed proposed AMLI topology. The DG output voltage (generally low voltage) is stepped up to the required level of voltage using high-gain DC-DC converter. Proposed AMLI topology consists of capacitors at the primary side. The output of high-gain DC-DC converter is fed to split voltage balance single-input multi-output (SIMO)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
17
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(17 citation statements)
references
References 10 publications
0
17
0
Order By: Relevance
“…When the transferred power is relatively low, the HPS controlled converter is modulated with TPS. When the power is large enough, decreases to 0, and the converter is EPS modulated [26]. Which means that the transmission power is independent of the phase-shift angle , but is mainly dominated by the phaseshift angle φ.…”
Section: Hps Control Strategymentioning
confidence: 99%
“…When the transferred power is relatively low, the HPS controlled converter is modulated with TPS. When the power is large enough, decreases to 0, and the converter is EPS modulated [26]. Which means that the transmission power is independent of the phase-shift angle , but is mainly dominated by the phaseshift angle φ.…”
Section: Hps Control Strategymentioning
confidence: 99%
“…Based on the above about the function of the magnetic field, and comparing to the conventional methods of black powder removal, and also based on the abilities of computerized systems for monitoring and/or controlling functions [19][20][21][22][23][24][25][26][27][28][29][30][31][32], the presented method in this paper focuses on controlling the level, location, and polarity of the allocated magnetic field in order to remove the black powder from crude oil. On the other hand, due to adopting the electrical resistivity measuring for well logging development [33], a new design of resistivity sensor in presented in this study in order to sense the crude oil resistivity will be presented through which the proposed system's performance can be evaluated.…”
Section: Proposed Idea and System Designmentioning
confidence: 99%
“…Cascaded H Bridge topology is gaining popularity due to its simple structure [6][7][8]. The absence of diodes and capacitor in the circuit adds more attraction.…”
Section: Introductionmentioning
confidence: 99%
“…Level 5 (Vo = V3) Int J Elec & Comp Eng ISSN: 2088-8708  Modular multilevel inverter for renewable energy applications (A. Arikesh) (f). Level 6 (V o = V 3 +V 1 ) Switching sequence for circuit i The Modular 49 level Modified H bridge type ACMLI follows the same mathematical expressions for the values of DC voltage sources, Number of stepsgenerates and maximum output voltage (ie) (1), (2),(3) and(4)is satisfied by the Modular 49 level Modified H bridge type ACMLI also, for this circuit the number of power electronic components required is governed by different equation and is given below (7).…”
mentioning
confidence: 99%