2018
DOI: 10.1093/jbcr/iry010
|View full text |Cite
|
Sign up to set email alerts
|

Grip and Muscle Strength Dynamometry in Acute Burn Injury: Evaluation of an Updated Assessment Protocol

Abstract: External stabilization is reported to improve reliability of hand-held dynamometry, yet this has not been tested in burns. We aimed to assess the reliability of dynamometry using an external system of stabilization in people with moderate burn injury and explore construct validity of strength assessment using dynamometry. Participants were assessed on muscle and grip strength three times on each side. Assessment occurred three times per week for up to 4 weeks. Within-session reliability was assessed using intr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
1
0
4

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 22 publications
0
1
0
4
Order By: Relevance
“…No teste de Thomas a média foi de 32,64° Todos os participantes demonstraram média de redução da força de preensão palmar segundo os dados da literatura 10,11 (Tabela 3). Apenas o paciente dois (28kgf) demonstrou força de preensão preservada.…”
Section: Resultsunclassified
See 3 more Smart Citations
“…No teste de Thomas a média foi de 32,64° Todos os participantes demonstraram média de redução da força de preensão palmar segundo os dados da literatura 10,11 (Tabela 3). Apenas o paciente dois (28kgf) demonstrou força de preensão preservada.…”
Section: Resultsunclassified
“…A força de preensão manual apresentou média inferior à de uma população jovem saudável e próxima aos valores esperados para idosos 11 . Os dados do estudo também foram inferiores a um estudo realizado na Austrália Ocidental com 38 pacientes queimados, cuja SCQ era de no máximo 40%, porém os participantes não tinham lesões nas mãos 10 .…”
Section: Discussionunclassified
See 2 more Smart Citations
“…This muscle force measure is not a direct measure of quadriceps muscle force alone, but a compound measure of hip flexor and knee extensor muscles. A fixation band, fixed around the bed frame, provided the necessary counter-resistance to ensure isometric contraction during the test [ 63 ]. This test position was chosen to make muscle force assessment possible for bed-bound participants whose joint range of motion is too limited to reach traditional positions of muscle force assessment (e.g.…”
Section: Methodsmentioning
confidence: 99%