2012
DOI: 10.3329/jemc.v1i2.11466
|View full text |Cite
|
Sign up to set email alerts
|

Gross Morphological Variation in Preterm Placenta in Gestational Diabetes Mellitus and Pregnancy Induced Hypertension

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 15 publications
1
11
0
Order By: Relevance
“…In the present study it was found to be more significant than Boyd et al [22] findings of which was 23% more in GDM than the normal. Also the numbers of cotyledons were increased in GDM [23] in the present study.…”
Section: Control (N=48) Range (Mini-maxi) Gdm (N=48) Range (Mini-maxisupporting
confidence: 64%
“…In the present study it was found to be more significant than Boyd et al [22] findings of which was 23% more in GDM than the normal. Also the numbers of cotyledons were increased in GDM [23] in the present study.…”
Section: Control (N=48) Range (Mini-maxi) Gdm (N=48) Range (Mini-maxisupporting
confidence: 64%
“…In the present study, the gross anatomic features of placental weight, thickness and diameter were significantly greater in GDM (p<0.0001) as compared to normal and coincides with earlier studies. 23,24 Weight of the babies was found to be significantly high when compared to the normal cases which can be attributed to one of the impact of the hyperglycaemia in GDM conditions. In the present study, the same has been revealed with the foetoplacental index which was calculated from weight of the baby/weight of the placenta and was found to be significant (p<0.02).…”
Section: Discussionmentioning
confidence: 94%
“…Then, another maximum diameter was measured at the right angle to the first measured diameter and the mean of two measurements was taken as the diameter of the placenta expressed in centimeter. 20 …”
Section: Methodsmentioning
confidence: 99%
“…Placentae were weighed using a weighing machine scaled in gram and the shape and presence of accessory lobe were recorded after proper observation to be categorized as round, oval, or irregular in shape. 20 , 23 , 24 After placing each placenta on the fetal surface, with the help of a long needle, the placental thickness was measured at five different points where the placentae were arbitrarily divided into three zones by drawing two circles on the maternal side. One thickness was measured from the Center of the central zone, two from the middle zone, and another two from the peripheral zone.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation