Gypsum scaling during forward osmosis process—a direct microscopic observation study

Abstract: A B S T R A C TThis study investigated the effect of supersaturation index (SI), ionic strength, membrane orientation, and antiscalant (AS) addition on gypsum scaling during forward osmosis (FO) desalination. Scaling tests were performed in a cross-flow FO system, and the development of gypsum scalants on FO membrane was directly observed using an optical microscope integrated with the FO filtration cell. Greater surface coverage by gypsum crystals and larger crystal sizes occurred on the scaled FO membranes f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 48 publications
0
4
0
Order By: Relevance
“…It is worthwhile to note that most of the existing studies on inorganic scaling in ODMPs focused on the use of gypsum as model scale that is independent of solution pH and has relatively high solubility [28,31,35,69,70,205,206]. Only few studies reported other types of scaling [80,186].…”
Section: Inorganic Scaling In Odmpsmentioning
confidence: 99%
“…It is worthwhile to note that most of the existing studies on inorganic scaling in ODMPs focused on the use of gypsum as model scale that is independent of solution pH and has relatively high solubility [28,31,35,69,70,205,206]. Only few studies reported other types of scaling [80,186].…”
Section: Inorganic Scaling In Odmpsmentioning
confidence: 99%
“…In this study, FS containing Ca 2+ and SO 4 2− were used to investigate the impact of scaling on TFC and CTA-W(P). The membranes were tested in AL-FS mode with mitigated internal scaling [ 50 ]. Water flux of TFC and CTA-W(P) in the scaling tests are shown in Figure 5 .…”
Section: Resultsmentioning
confidence: 99%
“…The tests were performed in the AL-FS mode. This mode is preferred in FO applications with low scaling/fouling potential as it can eliminate the internal clogging of support layer and achieve more stable flux in long-term operation [ 50 ]. In the scaling tests, mixed solution containing Na 2 SO 4 (72 mM), CaCl 2 (26.1 mM), and NaCl (10 mM) was used as FS, of which the gypsum saturation index (SI) was 2.0 [ 51 ].…”
Section: Methodsmentioning
confidence: 99%
“…When the concentration of these salts in the feed exceeds their solubility at higher water recovery rates, precipitation may occur near or on the membrane surface, leading to scaling of the membrane surface and flux decline [44,45]. Amongst the various scaling compounds reported in the literature are silica, calcium carbonate, gypsum and calcium sulphate [45][46][47][48][49][50].…”
Section: Inorganic Scalingmentioning
confidence: 99%