2006
DOI: 10.1109/tie.2006.882014
|View full text |Cite
|
Sign up to set email alerts
|

$H^infty$Control of the Neutral Point in Four-Wire Three-Phase DC–AC Converters

Abstract: Abstract-Inverters used as the interface for a distributed generator in a three-phase four-wire system sometimes operate with a large neutral current because of unbalanced loads and singlephase (possibly nonlinear) loads. Voltage balance within the dc-link of the inverter is important for proper operation of the inverter, and the neutral current is a significant disturbance to this. It is preferable to use fast acting control rather than dissipative balancing or large-valued capacitors. This paper develops a l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
43
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 81 publications
(43 citation statements)
references
References 20 publications
0
43
0
Order By: Relevance
“…Due to the presence of a balanced dc link (see [8], [9]), we may regard this system as three independent single-phase systems, as shown in Fig. 1, and hence there is no need to study here the three-phase behavior of the system.…”
Section: System Modelingmentioning
confidence: 99%
See 2 more Smart Citations
“…Due to the presence of a balanced dc link (see [8], [9]), we may regard this system as three independent single-phase systems, as shown in Fig. 1, and hence there is no need to study here the three-phase behavior of the system.…”
Section: System Modelingmentioning
confidence: 99%
“…Normally, the high-frequency poles can be reduced using various controller/model reduction techniques, which is a topic of wide interest. Here, we use a different approach from that used in [18], [8], [9] to decrease the controller bandwidth: we do not minimize the -norm of but find a suboptimal controller such that (which is larger than the minimal value 17.37). Such a controller (obtained using the hinfsyn routine in MATLAB is (9), shown at the bottom of the page.…”
Section: Controller Designmentioning
confidence: 99%
See 1 more Smart Citation
“…In Figure 8, u o represents the output voltage of the LC filter, whereas M represents the point neutral point between two switches, S M and S M . Even though the configuration in this topology does not need expensive and large capacitors and produces lower ripple on the DC link voltage, however, using two extra switches lead to a complex control system [47]. Additionally, the split DC-link voltage is about 15% less as compared to the AC voltage in this configuration [48].…”
Section: Three Phase Four-leg Vsi With An Output Filtermentioning
confidence: 96%
“…To mitigate the neutral current in a 3P4W system, various shunt inverter configurations have been studied, namely, two-split capacitor (2C) [130], [131], four-leg capacitor (4L) [131]- [141], and three-H bridge (3HB). 6 shows the 3P4W MFI configurations based on 2C, 4L, and 3HB topologies.…”
Section: A Power Circuit Structurementioning
confidence: 99%