2021
DOI: 10.3390/su13073709
|View full text |Cite
|
Sign up to set email alerts
|

Harmonic Analysis of Grid-Connected Solar PV Systems with Nonlinear Household Loads in Low-Voltage Distribution Networks

Abstract: Grid-connected rooftop and ground-mounted solar photovoltaics (PV) systems have gained attraction globally in recent years due to (a) reduced PV module prices, (b) maturing inverter technology, and (c) incentives through feed-in tariff (FiT) or net metering. The large penetration of grid-connected PVs coupled with nonlinear loads and bidirectional power flows impacts grid voltage levels and total harmonic distortion (THD) at the low-voltage (LV) distribution feeder. In this study, LV power quality issues with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 45 publications
(16 citation statements)
references
References 35 publications
0
16
0
Order By: Relevance
“…21 are 11.57% and 10.67% respectively, which are higher than the standards and unacceptable. According to IEEE Standard 519-2014 [33], the THD of the PCC voltage should be smaller than 8% (5%) in the low (medium) voltage application that the PCC bus voltage is lower than 69 kV [34]. To reduce the harmonics, suitable optimization for the inverter parameters is necessary.…”
Section: Simulation Analysis Of Pcc Voltage Harmonicsmentioning
confidence: 99%
“…21 are 11.57% and 10.67% respectively, which are higher than the standards and unacceptable. According to IEEE Standard 519-2014 [33], the THD of the PCC voltage should be smaller than 8% (5%) in the low (medium) voltage application that the PCC bus voltage is lower than 69 kV [34]. To reduce the harmonics, suitable optimization for the inverter parameters is necessary.…”
Section: Simulation Analysis Of Pcc Voltage Harmonicsmentioning
confidence: 99%
“…The major focus of this research, dealing with the impact of grid-connected PV systems, is based on power quality analysis and harmonic mitigation techniques [17][18][19]. In this article, the focus is on the evaluation of electric power quantities based on different solar irradiance levels.…”
Section: Used Methodologymentioning
confidence: 99%
“…II. choosing the field parameters, number of connected panels, and the system capacities and applying the Monte-Carlo method to handle the variations in the irradiance, which significantly affect the THD [24].…”
Section: Modeling Of Total Harmonic Distortion Of a Photovoltaic Mult...mentioning
confidence: 99%