1993
DOI: 10.1016/0584-8539(93)80108-m
|View full text |Cite
|
Sign up to set email alerts
|

Hazards associated with the use of electrochemically prepared substrates in the qualitative analysis of aqueous solutions by surface-enhanced Raman spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

1995
1995
2006
2006

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…Its reactions with formaldehyde to give methylol derivatives and ultimately thermosetting resins have been studied intensively, and melamine itself has therefore become a product of large-scale manufacture and use. Spectroscopic studies based on optical absorption, 13 C NMR, or vibrational spectroscopies (IR, FT-IR, Raman, and FT-Raman) can provide insight into the molecular structure of these melamine-based species. 1 The complexity of the melamine/ formaldehyde systems makes direct use of the spectroscopic techniques difficult.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations
“…Its reactions with formaldehyde to give methylol derivatives and ultimately thermosetting resins have been studied intensively, and melamine itself has therefore become a product of large-scale manufacture and use. Spectroscopic studies based on optical absorption, 13 C NMR, or vibrational spectroscopies (IR, FT-IR, Raman, and FT-Raman) can provide insight into the molecular structure of these melamine-based species. 1 The complexity of the melamine/ formaldehyde systems makes direct use of the spectroscopic techniques difficult.…”
Section: Introductionmentioning
confidence: 99%
“…The extremely different spectral behavior of silver SERS substrates roughened in situ or ex situ has been shown clearly. 13 Alternatively, surfactants may be used to remove the analyte from the electrode surface. 14 In the current study, cetylpyridinium chloride (C 16 H 33 N + C 5 H 5 Cl -, CPC) is used.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Observation of SERS using near infrared at 1064 nm has been demonstrated recently, using new-generation Fourier transform Raman spectrometers. Although only a few observations by this technique have been published [11][12][13][14][15][16][17][18][19], a number of experimental advantages are already apparent. These include the speed of data acquisition, the ease of sample alignment when using the backscattering geometry, and larger enhancement factor than that obtained when in the visible spectral region [11,19].…”
Section: Introductionmentioning
confidence: 99%