HeartMate 3—a “Step” in the right direction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 25 publications
1
4
0
Order By: Relevance
“…28 Finally, HeartMate 3 has been described as a highly hemocompatible pump based on its design with no mechanical contact points, large gaps, and fused titanium microspheres on its blood contact surfaces which may promote the formation of a biologic barrier to further help decrease the risk of the thrombosis. 29 Based on this previous literature and our observations, we can speculate that the risk for thrombus formation could be significantly mitigated with the use of a TPScoated titanium plug. Indeed, after the complete coverage of the plug by autologous tissues, the foreign surface will not be in direct contact with the blood stream anymore.…”
Section: Discussionsupporting
confidence: 66%
See 1 more Smart Citation
“…28 Finally, HeartMate 3 has been described as a highly hemocompatible pump based on its design with no mechanical contact points, large gaps, and fused titanium microspheres on its blood contact surfaces which may promote the formation of a biologic barrier to further help decrease the risk of the thrombosis. 29 Based on this previous literature and our observations, we can speculate that the risk for thrombus formation could be significantly mitigated with the use of a TPScoated titanium plug. Indeed, after the complete coverage of the plug by autologous tissues, the foreign surface will not be in direct contact with the blood stream anymore.…”
Section: Discussionsupporting
confidence: 66%
“…This modification, together with new anticoagulation recommendations, led to a decline of pump exchange for thrombus from 7% (0.07 EPPY) to in 2% (0.02 EPPY) 28 . Finally, HeartMate 3 has been described as a highly hemocompatible pump based on its design with no mechanical contact points, large gaps, and fused titanium microspheres on its blood contact surfaces which may promote the formation of a biologic barrier to further help decrease the risk of the thrombosis 29 …”
Section: Discussionmentioning
confidence: 99%
“…It has magnetic levitation and wide gap spaces to reduce blood damage. It does not contain any mechanical or hydrodynamic bearings [23,24].…”
Section: Tah Pulsatilementioning
confidence: 99%
“…Bartoli et al reported that pulsatile flow preserved physiological values of myocardial energy utilization and vascular hemodynamics, such that when pulsatile unloading increased, normal LV pressures were maintained; however, under continuous flow, the pressure–volume relationship collapsed and the aortic valve remained closed [119]. To combat the complications associated with continuous-flow VADs, the HeartMate 3, a centrifugal pump, was designed to have intermittent speed reduction, to reduce stasis in the pump, as well as providing artificial pulsatility [120,121]. This device could be utilized as a cardioprotective strategy, targeting complications such as AI and improving LV systolic and diastolic function, as well as end-organ and microcirculatory perfusion.…”
Section: Mechanical Circulatory Support (Mcs)mentioning
confidence: 99%