2012
DOI: 10.1016/j.ijheatmasstransfer.2012.03.063
|View full text |Cite
|
Sign up to set email alerts
|

Heat transfer characteristics of submerged jet impingement boiling of saturated FC-72

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
3
2
2

Relationship

1
6

Authors

Journals

citations
Cited by 43 publications
(22 citation statements)
references
References 24 publications
0
22
0
Order By: Relevance
“…Several single-jet studies in the literature experienced a saturation temperature overshoot, where wall temperatures were required to be much higher than the fluid saturation temperature to initiate boiling [9,45]. In the current study, the interaction of neighboring jets on the impingement surface may explain the absence of any overshoot or boiling hysteresis.…”
Section: Additional Observationsmentioning
confidence: 60%
See 1 more Smart Citation
“…Several single-jet studies in the literature experienced a saturation temperature overshoot, where wall temperatures were required to be much higher than the fluid saturation temperature to initiate boiling [9,45]. In the current study, the interaction of neighboring jets on the impingement surface may explain the absence of any overshoot or boiling hysteresis.…”
Section: Additional Observationsmentioning
confidence: 60%
“…In the flow field of a single impinging jet, boiling behavior is most often observed beginning away from the stagnation region of the jet, often at a hydraulic jump or heater boundary, extending inward toward the jet [45,46]. Critical heat flux is believed to follow a similar pattern [9].…”
Section: Critical Heat Fluxmentioning
confidence: 99%
“…Experiments by Cardenas and Narayanan [14][15][16][17][18]. Details on the experimental facility and experiments for jet impingement boiling using subatmospheric water and FC-72 are provided else where [18].…”
Section: Review Of Data Used In Correlationmentioning
confidence: 99%
“…To develop the jet impingement CHF correlation, the number of jet impingement CHF data points considered from the studies by Cardenas and Narayanan [14][15][16][17][18] is 46 (excluding pool boiling cases). Table 4 presents uncertainty estimates for measured and determined variables [23], Data reproducibility was studied by performing repetitions and replications of experiments and it was found that CHF varied between 4% and 6% [18].…”
Section: Review Of Data Used In Correlationmentioning
confidence: 99%
See 1 more Smart Citation