2021
DOI: 10.21037/atm-21-1135
|View full text |Cite
|
Sign up to set email alerts
|

Hemodynamic evaluation and in vitro hemolysis evaluation of a novel centrifugal pump for extracorporeal membrane oxygenation

Abstract: Background: The STM CP-24 I centrifugal pump is a newly developed centrifugal pump for extracorporeal membrane oxygenation equipment. This study aimed to combine hydraulic experiments, hemodynamic numerical simulations, and standard in vitro hemolysis experiments to investigate the comprehensive performance of this centrifugal pump. Methods:In vitro experiments were first done to obtain the pressure-flow data of the centrifugal pump in its working range to evaluate its hydraulic performance. Next, the commonly… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…10 sheep were randomly divided into the V‐A (veno‐arterial) group ( n = 5) that underwent V‐A ECMO and the V‐V (veno‐venous) group ( n = 5) that underwent V‐V ECMO. All were scheduled to be supported for 168 h. For the V‐V group, the circuits were composed of Hilite7000LT (XENIOS, Heilbronn, Germany) 11 and STM CP‐24 I centrifugal pump (Jiangsu STMed Technologies Co., Suzhou, China) 12 . The 23 Fr Avalon Elite (Maquet, Rastatt, Germany) double‐lumen cannula was inserted through the right external jugular vein.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…10 sheep were randomly divided into the V‐A (veno‐arterial) group ( n = 5) that underwent V‐A ECMO and the V‐V (veno‐venous) group ( n = 5) that underwent V‐V ECMO. All were scheduled to be supported for 168 h. For the V‐V group, the circuits were composed of Hilite7000LT (XENIOS, Heilbronn, Germany) 11 and STM CP‐24 I centrifugal pump (Jiangsu STMed Technologies Co., Suzhou, China) 12 . The 23 Fr Avalon Elite (Maquet, Rastatt, Germany) double‐lumen cannula was inserted through the right external jugular vein.…”
Section: Methodsmentioning
confidence: 99%
“…All were scheduled to be supported for 168 h. For the V-V group, the circuits were composed of Hilite7000LT (XENIOS, Heilbronn, Germany) 11 and STM CP-24 I centrifugal pump (Jiangsu STMed Technologies Co., Suzhou, China). 12 The 23 Fr Avalon Elite (Maquet, Rastatt, Germany) double-lumen cannula was inserted through the right external jugular vein. For the V-A group, the circuits were composed of BE-PLS 2050 (Maquet, Rastatt, Germany) 11 and STM CP-24 I centrifugal pump.…”
Section: Animals and Ecmo Proceduresmentioning
confidence: 99%
“…The development of pulsatile pumps, first used in the 1950s, paved the way for continuous flow pumps that are now commonly used in heart transplants and as cardiac assist devices. The ongoing advancements in blood pump technology continue to improve patient outcomes and redefine the field of cardiology [ 89 ]. Research carried out in this area improves the construction of pumps, which leads to increasingly better results.…”
Section: Medical Devicesmentioning
confidence: 99%
“…These studies provided important insights for understanding the effects of ECMO from various perspectives spanning from systemic hemodynamics to microcirculation perfusion, nevertheless, most of them were restricted by available techniques for in vivo measurements, making the findings less comprehensive or lack quantitative details on some variables of interest (e.g., flow patterns near the cannulation sites, oxygen saturations in different end-organs). Such limitations of in vivo studies may be partly overcome by in vitro or ex-vivo studies, especially those based on mock loop models ( Ki et al, 2019 ; Fu et al, 2021 ; Caspari et al, 2022 ; Rozencwajg et al, 2022 ; Sayed et al, 2022 ). This sort of studies are however limited by the high cost of fabricating models mimicking the complex vascular structure and difficulties in representing various cardiovascular properties using artificial devices.…”
Section: Introductionmentioning
confidence: 99%