“…Each of the crates mounted on the OTR superlayer frames contains TDC boards and a daughter board of the Fast Control System (FCS) [9,10]. The crate control monitors the voltage and temperature of the power supply and the speed of the cooling fan.…”
Section: Tdc Crate Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…Each of the crates mounted on the OTR superlayer frames contains TDC boards and a daughter board of the Fast Control System (FCS) [9,10]. The crate control monitors the voltage and temperature of the power supply and the speed of the cooling fan.…”
Section: Tdc Crate Controlmentioning
confidence: 99%
“…A reference track consists of a track segment in the VDS together with an associated RICH ring or ECAL cluster. 9 In order to keep the contamination by unphysical tracks (e.g. detector or reconstruction artefacts) in the reference sample low, each reference track must be consistent with originating from a K Then in the vicinity of each reference track an OTR segment matching with the same VDS segment is searched.…”