Heterogeneous and homogeneous electrochemiluminoimmunoassays of hTSH at disposable oxide-covered aluminum electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2006
2006
2022
2022

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(26 citation statements)
references
References 18 publications
0
26
0
Order By: Relevance
“…The effective area of the electrode in this cell was 63.6 mm 2 . A laboratory-made coulostatic pulse generator [22] was applied to generate cathodic pulses and a pulse generator was adjusted to yield cathodic pulses with 40 C of charge and −40 V of voltage with frequency of 20 Hz. Contact angles were measured with drop shape analysis system (Kruss).…”
Section: Instrumentation and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The effective area of the electrode in this cell was 63.6 mm 2 . A laboratory-made coulostatic pulse generator [22] was applied to generate cathodic pulses and a pulse generator was adjusted to yield cathodic pulses with 40 C of charge and −40 V of voltage with frequency of 20 Hz. Contact angles were measured with drop shape analysis system (Kruss).…”
Section: Instrumentation and Methodsmentioning
confidence: 99%
“…A distinct advantage of HECL over anodic ECL is that various luminophores with different optical and redox properties can be simultaneously excited [14,20]. HECL has been previously used for biorecognition detection in immunoassays [12,[21][22][23]. Capturing antibodies were physically adsorbed on oxide-coated aluminum [12,21,22] and silicon [23] electrodes and the biorecognition reaction was detected using target antibodies labeled with HECL labels.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurements were carried out using a coulostatic pulse generator [35] with 120 µC, 20 Hz, -50 V cathodic pulses. The ECL intensities of lucigenin were detected through an interference filter with a center wavelength at 500 nm and transmission band half-width of 10 nm, using single photon counting and apparatus described previously [36,37].…”
Section: Methodsmentioning
confidence: 99%
“…A separation could be done by binding antibody-A beads to the well bottom, by a filtration step or by using magnetic beads (Hall et al, 1999;Koskinen et al, 2004;Kulmala et al, 2002;McCrindle et al, 1985;Namba et al, 2000;Obenauer-Kutner et al, 1997;Okano et al, 1992;Sardesai et al, 2009;Sin et al, 2006;Soukka et al, 2001). All the described methods are based on particulate labels.…”
Section: Introductionmentioning
confidence: 99%