2007
DOI: 10.1109/tim.2007.890625
|View full text |Cite
|
Sign up to set email alerts
|

High-Accuracy Methods and Measurement Procedures for Power Quality Parameters Using the Digital Synchronous Sampling Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…Although many authors are concerned with the measurement of active, apparent and non-active power including reactive power (see [ 9 , 10 , 11 , 12 ]) even of distorted alternating currents and voltages (see [ 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 ]), there is no literature on the evaluation of uncertainty in power measurement with harmonics or with a phase-fired current waveform as required by standard [ 3 ]. The evaluation of uncertainty due to synchronous sampling of digital multimeters has been discussed in depth in [ 13 , 14 ], but no study has been found in the literature on the sensitivity of power measurements to certain processing parameters, such as the integration of the signals at a time other than the full period, nor the influence of the synchronization errors between the two DMMs on the power measurement, nor the method of signal integration.…”
Section: Introductionmentioning
confidence: 99%
“…Although many authors are concerned with the measurement of active, apparent and non-active power including reactive power (see [ 9 , 10 , 11 , 12 ]) even of distorted alternating currents and voltages (see [ 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 ]), there is no literature on the evaluation of uncertainty in power measurement with harmonics or with a phase-fired current waveform as required by standard [ 3 ]. The evaluation of uncertainty due to synchronous sampling of digital multimeters has been discussed in depth in [ 13 , 14 ], but no study has been found in the literature on the sensitivity of power measurements to certain processing parameters, such as the integration of the signals at a time other than the full period, nor the influence of the synchronization errors between the two DMMs on the power measurement, nor the method of signal integration.…”
Section: Introductionmentioning
confidence: 99%
“…However, in general, only part of the states of neurons is useful, especially for large-scale neural networks. Nowadays, more and more attentions have been paid to sample and measure states of neurons, and a lot of researches have been done on this issue [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Traditional measuring methods based on thermal converters only provide information about the root mean square value of the measured signal and are not suitable for the task, so alternative measurement techniques are required. At the reference level, a few national metrology institutes (NMIs) have developed metrology grade power and PQ measurement systems based on digital sampling techniques [2][3][4][5][6][7][8]. These measurement systems are complex and the resources required to design, build and validate them challenges even larger NMIs.…”
Section: Introductionmentioning
confidence: 99%