Eco-Efficient Materials for Mitigating Building Cooling Needs 2015
DOI: 10.1016/b978-1-78242-380-5.00009-1
|View full text |Cite
|
Sign up to set email alerts
|

High-albedo roof coatings for reducing building cooling needs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 54 publications
0
9
0
Order By: Relevance
“…Solar reflectance is a measure of the ability of a material to reflect incident solar radiation without absorbing it [23]. Infrared emittance measures the capability of the surface to re-emit the previously absorbed heat away from itself [24]. Their values are expressed as ratios that range from 0 to 1 without units.…”
Section: Methodsmentioning
confidence: 99%
“…Solar reflectance is a measure of the ability of a material to reflect incident solar radiation without absorbing it [23]. Infrared emittance measures the capability of the surface to re-emit the previously absorbed heat away from itself [24]. Their values are expressed as ratios that range from 0 to 1 without units.…”
Section: Methodsmentioning
confidence: 99%
“…In Figure 6, TR2-white had higher peaks of reflectance compared to TR1, being more responsive to the solar incoming radiation. For TR2-black, it is assumed a typical reflectance value of 4-8% [36]. TR2-black absorbs more of the incoming radiation, with peak value at 12:30.…”
Section: Tr2-green Compared With Black and White Coatingmentioning
confidence: 99%
“…Concerning the solar heat gains through incoming radiation, the reflectance variation between the surfaces affects the buildings' thermal performance. According to Pisello [36], a red natural clay tile solar reflectance is about 28 to 44%, while a grass-covered area typically is 20%. This difference is observed on the TR1 and TR2 measurements, where TR2-green reflected about 14% less than TR1.…”
Section: Tr2-green Compared With Black and White Coatingmentioning
confidence: 99%
“…The coatings can be classified according to their binders, such as cementitious or elastomeric coatings. Alternatively, the coatings can also be categorized according to their carriers, such as solvent-or water-based coatings [33]. Essentially, for application on high-albedo roofs, the coatings are required to possess superficial thermal-optical properties that are appropriate for maintaining, under exposure to solar radiation, surface temperatures that are appreciably lower than those of conventional roofs.…”
Section: Introductionmentioning