1987
DOI: 10.1088/0022-3700/20/22/015
|View full text |Cite
|
Sign up to set email alerts
|

High-energy photoelectron C 1s and O 1s shake-up spectra of CO

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

9
55
0

Year Published

1991
1991
1998
1998

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 73 publications
(64 citation statements)
references
References 21 publications
9
55
0
Order By: Relevance
“…To our knowledge, the only applications [57,58] of Green's function methods to core electron shake-up spectra are due to the so-called algebraic diagrammatic construction, A D C (~) and A D C (~) , methods, which are, respectively, complete thirdand fourth-order approximation schemes to the one-particle Green's function [57]. Within this scheme, the ionization energies and spectroscopic factors are obtained as eigenpairs of a Hermitian secular matrix and computed with techniques similar to those used in diagonalizing large CI matrices.…”
Section: Green's Function Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…To our knowledge, the only applications [57,58] of Green's function methods to core electron shake-up spectra are due to the so-called algebraic diagrammatic construction, A D C (~) and A D C (~) , methods, which are, respectively, complete thirdand fourth-order approximation schemes to the one-particle Green's function [57]. Within this scheme, the ionization energies and spectroscopic factors are obtained as eigenpairs of a Hermitian secular matrix and computed with techniques similar to those used in diagonalizing large CI matrices.…”
Section: Green's Function Methodsmentioning
confidence: 99%
“…The construction and solution of the secular matrix is actually simplified in the core electron problem since one is allowed to neglect the core-valence correlation (cf. singleoccupancy restriction, neglect of semi-internal CI, see Section 3.2), which leads to a decoupling of the secular problem [58,87]. The secular matrix is then defined by a configuration space comprising lh, 2h-lp, and 3h-2p states with exactly one core-level vacancy.…”
Section: Green's Function Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A straight application of RPA on X-ray emission leads to errors larger than 10 eV for first-row molecules. Furthermore, some core electron processes are delicately dependent on the precise nature of the electron correlation and would require higher-order propagator methods if the unrelaxed ground state is used as the reference state [16]. Higherorder expansions and/or level shifting techniques are necessary to obtain solutions with proper core occupations.…”
Section: Calculation Of Molecular Core Hole States and Spectramentioning
confidence: 99%