High-Pitch 128-Slice Dual-Source CT for the Assessment of Coronary Stents in a Phantom Model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…A previous study on the third-generation dual-source CT system showed that, depending on the stent's orientation, up to 80% lumen visibility on average can be achieved in 3.0-mm metal stents when applying new iterative reconstruction kernels (14). However, comparison of these results to former studies is limited because of the differences in CT systems, reconstruction kernels, and especially the selection of coronary stents (4,9,12). Therefore, the exact degree of diagnostic improvement deriving from the use of third-generation dualsource CT systems remained unclear, generating a need for this comparison study.…”
Section: Discussionmentioning
confidence: 94%
See 3 more Smart Citations
“…A previous study on the third-generation dual-source CT system showed that, depending on the stent's orientation, up to 80% lumen visibility on average can be achieved in 3.0-mm metal stents when applying new iterative reconstruction kernels (14). However, comparison of these results to former studies is limited because of the differences in CT systems, reconstruction kernels, and especially the selection of coronary stents (4,9,12). Therefore, the exact degree of diagnostic improvement deriving from the use of third-generation dualsource CT systems remained unclear, generating a need for this comparison study.…”
Section: Discussionmentioning
confidence: 94%
“…The finding of reduced visible stent lumen diameter at 100 kVp is presumably based on the increase of beam hardening or, rather, effects that have been described before as blooming and "halo effect" (9,12). These effects are caused by very dense materials like coronary calcification or metallic stent struts and limit the evaluation of the stent's lumen in the vicinity thereof (15).…”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…4,5 However, through increasing number of detector rows, increasing temporal resolution and improved reconstruction kernels, the image quality has been substantially improved. [6][7][8][9][10][11][12][13][14][15][16] A previous study revealed that a third-generation dual-source CT scanner (SOMATOM Force; Siemens Healthcare, Forchheim, Germany) enabled a lumen visibility of up to 80% in metal stents while the stents were at rest. 17 To evaluate the influence of cardiac motion on stent lumen visualization in the same third-generation dual-source CT scanner, we employed a pulsatile heart model (CoroSim®; Mecora, Aachen, Germany) (Figures 1 and 2) to evaluate differences in visible stent lumen diameter between motion and standstill.…”
Section: Introductionmentioning
confidence: 99%