2019
DOI: 10.1111/ggr.12283
|View full text |Cite
|
Sign up to set email alerts
|

High‐Precision Measurement of Stable Cr Isotopes in Geological Reference Materials by a Double‐Spike TIMS Method

Abstract: Chromium (Cr) isotopes have been widely used in various fields of Earth and planetary sciences. However, high‐precision measurements of Cr stable isotope ratios are still challenged by difficulties in purifying Cr and organic matter interference from resin using double‐spike thermal ionisation mass spectrometry. In this study, an improved and easily operated two‐column chemical separation procedure using AG50W‐X12 (200–400 mesh) resin is introduced. This resin has a higher cross‐linking density than AG50W‐X8, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
8
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 60 publications
3
8
0
Order By: Relevance
“…Thermo 2), were also measured in this study to test the data quality. Our data are consistent with previous studies (Bonnand et al, 2016b;Liu et al, 2019;Schoenberg et al, 2016;Sossi et al, 2018;Wu et al, 2020;Zhu et al, 2019c), which suggests that our δ 53 Cr data are accurate to the stated uncertainties.…”
Section: Mass-dependent Cr Isotope (δ 53 Cr) Measurementssupporting
confidence: 93%
“…Thermo 2), were also measured in this study to test the data quality. Our data are consistent with previous studies (Bonnand et al, 2016b;Liu et al, 2019;Schoenberg et al, 2016;Sossi et al, 2018;Wu et al, 2020;Zhu et al, 2019c), which suggests that our δ 53 Cr data are accurate to the stated uncertainties.…”
Section: Mass-dependent Cr Isotope (δ 53 Cr) Measurementssupporting
confidence: 93%
“…The mass-dependent δ 53 Cr data (measured by double spike technique) for BHVO-2 and PCC-1 are also consistent with the literature data (Bonnand et al, 2016b;Liu et al, 2019;Schoenberg et al, 2016;Sossi et al, 2018;Wu et al, 2020;Zhu et al, 2019c).…”
Section: Resultssupporting
confidence: 89%
“…(Bio-Rad) resin. AG 50W-X12 resin was used in the chromatography procedure as it as a higher cross-linkage, smaller wet bead size, and smaller molecular weight limits than the Bio-Rad AG50W-X8 (200 ~ 400 mesh), which will give better separation of Cr and Mg. 41 The column chromatography used in this study is described in Table 1 and an example elution curve for the BHVO-2 reference material is shown in Fig. 1.…”
Section: Sample Preparation and Digestion Sample Powders (~50 Mg)mentioning
confidence: 99%
“…The third column contains 0.33 ml of Bio-Rad AG50W-X12 (200 ~ 400 mesh) cation exchange resins. 41 The resin was cleaned with 2 ml 6 M HCl and 1 ml MQ water, then preconditioned with 1 ml 0.5 M HNO3. Samples are loaded in 1 ml 0.5 M HNO3, followed by 2.5 ml (1 + 1.5) 1 M HF to effectively remove residual Ti, Al, Fe and V, and 6 (3 + 3) ml 1 M HCl to remove remaining Mg, K and Ca, and Na.…”
Section: Sample Preparation and Digestion Sample Powders (~50 Mg)mentioning
confidence: 99%