2023
DOI: 10.1109/jsen.2023.3265023
|View full text |Cite
|
Sign up to set email alerts
|

High-Precision Measuring System for Internal Deformation Monitoring Pipeline of Rockfill Dams: Design and Validation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2024
2024
2025
2025

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(1 citation statement)
references
References 18 publications
0
1
0
Order By: Relevance
“…In recent years, some scholars have utilized flexible small-caliber pipelines to conduct research on deformation detection and safe operation and maintenance of large-scale infrastructures, such as the measurement of settlement deformation inside dams. Li et al [5][6][7] buried flexible pipes in the horizontal plane inside the dam, and measured the shape change of the flexible pipes by PMR (Figure 1) with an integrated odometer, so as to obtain the vertical and horizontal deformation inside the dam. Unlike general urban underground pipelines and energy pipelines, where the measurement accuracy is about 0.2% to 0.03% of the length of the pipeline, the measurement accuracy of the pipeline for monitoring the internal deformation of the dam is much higher, and the accuracy of the pipeline for a length of 100 meters needs to reach the millimeter level, i.e., no more than 0.01% of the length of the pipeline.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, some scholars have utilized flexible small-caliber pipelines to conduct research on deformation detection and safe operation and maintenance of large-scale infrastructures, such as the measurement of settlement deformation inside dams. Li et al [5][6][7] buried flexible pipes in the horizontal plane inside the dam, and measured the shape change of the flexible pipes by PMR (Figure 1) with an integrated odometer, so as to obtain the vertical and horizontal deformation inside the dam. Unlike general urban underground pipelines and energy pipelines, where the measurement accuracy is about 0.2% to 0.03% of the length of the pipeline, the measurement accuracy of the pipeline for monitoring the internal deformation of the dam is much higher, and the accuracy of the pipeline for a length of 100 meters needs to reach the millimeter level, i.e., no more than 0.01% of the length of the pipeline.…”
Section: Introductionmentioning
confidence: 99%